Ltf Sensor Menu (Menu); Remote Input - Banner LTF Instruction Manual

Time of flight laser distance sensor
Hide thumbs Also See for LTF:
Table of Contents

Advertisement

LTF Time Of Flight Laser Distance Sensor Instruction Manual
LTF Sensor Menu (MENU)
 Access the Sensor Menu by pressing Enter from Run mode. The Sensor Menu is also accessible from the Quick Menu: navi-
gate to MENU and press Enter. The Sensor Menu includes several submenus that provide access to view and change sen-
sor settings and to view sensor information. 
See "Sensor Menu Full Map" on page
 Remote Input 
Use the remote input to program the sensor remotely. The remove input is disabled by default. Activate remote input using
the buttons to navigate to the Input Type menu option. 
The remote input provides limited programming options and is Active Low by default. For Active Low, connect the gray input
wire to ground (0 V DC), with a remote switch connected between the wire and ground. To use the Active High function, con-
figure the sensor for Active High using the buttons on the sensor, then connect the gray input wire to V+ (12 to 30 V DC).
Pulse the remote input according to the diagram and the instructions provided in this manual. 
The length of the individual programming pulses is equal to the value T: 0.04 seconds ≤ T ≤ 0.8 seconds. 
Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-second
 
timeout, or by pressing and holding Escape for 2 seconds. The sensor returns to Run mode without saving any new settings. 
 
14
Quick Menu Map (Window Mode)
Run
Mode
Sensor Menu
Run
MENU A_OUT
Mode
MENU D_OUT
MENU INPUT
MENU MEASURE
Select Menu Item
or
Press to Save Setting
MENU DISPLAY
MENU INFO
Go Back to Parent Menu
or
Press and Hold to Go Back
MENU RESET
to Run Mode
53 and the Menu sections of this manual for more information. 
Quick Menu
4mA Pt (value)
set value with
20mA Pt (value)
SPt1 Pt (value)
SPt2 Pt (value)
access Sensor
MENU
Menu (Top Menu)
Sensor Menu Basic Map
(See Sensor Menu Full Map for the complete map)
Access analog output settings
Access discrete output settings
Select input line settings (remote TEACH, trigger mode, etc.)
Select response speed and trigger measurement
Select display units, zero reference, shift, and orientation
View sensor information
Reset to factory defaults
© Banner Engineering Corp.
Save setting
and return to
Quick Menu
or
Cancel and
return to
Quick Menu
 
June 22, 2023