Encodercontrol - IAI SW-4000TL-10GE User Manual

High speed cmos trilinear camera
Table of Contents

Advertisement

SW-4000TL-10GE | SW-4000TL-SFP | User Manual (2.0)

EncoderControl

Configure settings for encoder control.
Related Topic:
Connecting Rotary Encoders
Encoder Control Item
EncoderSourceA
EncoderSourceB
EncoderDivider
EncoderFilter (ns)
EncoderStrobe (ns)
EncoderAveragingInterval
EncoderMaxIntervalFor
NonDecimationMode
Note: SW-4000TL-10GE
only
Setting Range
Default
Off
Line4 TTL In1
Line5 Opt In 1
Off
Line10 TTL In2
Line13 TTL In3
Off
Line4 TTL In1
Line5 Opt In 1
Off
Line10 TTL In2
Line13 TTL In3
1~ 4294967295
65536
0 ~ 150 (10 step) 0
10 ~ 2550 (10
10
step)
none
2 pulses
4 pulses
none
8 pulses
16 pulses
32 pulses
0 ~ 60
0
Select where to input the signal from the rotary encoder.
Select where to input the signal from the rotary encoder.
Set the number of triggers to be generated during one pitch of the
rotary encoder. The number of triggers is 65536 / (set value).
Apply a low-pass filter to prevent noise on the signal from the rotary
encoder and stabilize the signal for the specified number of cycles.
Set the strobe length of the Trigger signal generated from the rotary
encoder by the number of cycles.
When the reliability of the interval of the signal output from the rotary
encoder is low. (Some signal interval is extremely long or short). When
this function is enabled, internal processing is performed by averaging
the interval of several previous signals.
Set the maximum interval period of the output signal only if the
EncoderDivider is not set to an integer multiple of 65536.
- 79 -
Setting List (Feature Properties)
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw-4000tl-sfp

Table of Contents