Cybex 525T Treadmill Part Number
Error 96: Thermal Integrator of output current
Cause:
The drive has several over-current situations that can cause this:
• >200% Rated for 3 seconds (roughly 16A)
• >150% Rated for 1 minute (roughly 12A)
• >101% Rated for accumulated time (roughly =>8.1A)
Service:
• Check drive's cooling fan and heat sink for clogs.
• Verify line voltage isn't sagging.
• Check the belt/deck for wear.
• Check treadmill for physical obstructions, seized bearings, etc.
• Investigate actual line current with various weight users. Determine user weight, speed and incline
when error occurred.
Page 89 of 199