Error 8: Approaching Over-Temperature
Cause:
Drive is reporting a temperature of 100+°C
Service:
• Open controller and vacuum or blow out accumulated debris.
• Verify the drive's fan is functional, unclogged, and the heat sink vanes are clear of debris.
• Verify controller is secured to the mounting plate tightly.
• Inquire on conditions in which the unit generated the error condition (user weight, speed, incline,
etc.).