3. Operate the unit at all levels to verify proper operation.
Power Inlet
Tools Required:
• Phillips screwdriver
• Flat head screwdriver
Disconnect power source
1. Toggle the on/off (I/O) power switch to the off (O) position. The on/off (I/O) power switch is located
under the front end of the unit, or on the front right side panel.
2. Unplug the treadmill from the power outlet.
Remove motor cover
1. Loosen, but do not remove the two front cover screws securing the motor cover using a Phillips
screwdriver.
2. Remove motor cover by carefully lifting vertically. Do not break the four plastic connectors.
Cybex 525T Treadmill Part Number
Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing
maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Page 168 of 199
Item
Description
1
Motor Cover
2
Front Cover
3
Screws
4
Plastic Connectors
Qty.
1
1
2
4

Hide quick links: