Incline Motor
Tools Required:
• Phillips screwdriver
• Block, 4" (10 cm) (2)
• 9/16" Open end wrench
• 9/16" Socket wrench
• Tape measure
Disconnect power source
1. Toggle the on/off (I/O) power switch to the off (O) position. The on/off (I/O) power switch is located
under the front end of the unit, or on the front right side panel.
2. Unplug the treadmill from the power outlet.
Place blocks under frame
Lift the front of the treadmill with two people, have a third person place a 4" (10 cm ) block under each
side of the frame to support the front end of the treadmill. This will get the weight of the treadmill off the
elevation wheels and provide support.
Remove motor cover
1. Loosen, but do not remove the two front cover screws securing the motor cover using a Phillips
screwdriver.
Cybex 525T Treadmill Part Number
Shock and electrocution hazard.
• Unplug unit and let sit 10 minutes before cleaning or performing
maintenance.
• Electrical charge can remain in unit after unplugging.
• Keep water and liquids away from electrical parts.
Heavy equipment.
• At least two people must lift, move or assemble unit.
• Use safe lifting methods.