Error 6 - Membrane Fault (Stuck Key)
Cause:
Membrane is showing a key constantly activated (noticed at power-up.)
Service:
• Check the membrane and thumb controls for signs of fatigue, cracking, or possible moisture intrusion.
• Ensure the membrane connector is fully seated.
• Inspect the membrane cable for cuts, pinches, and all leads are fully inserted in their connectors.
• Replace the membrane and/or the thumb control switches.
Key list
Left and Right controls
Key
Description
1
Incline Down
2
Incline Up
3
Speed Down
4
Speed Up
Main controls
Key
Description
5
Volume Up
6
Volume Down
7
Channel Up or Next
8
Channel Down or Previous
9
STOP
11
Setup
12
Display option
13
Enter
14
Quick Start
15
Workouts
Cybex 525T Treadmill Part Number