Cybex 525T Treadmill Part Number
Error 15: Embedded A/V Device Failure
Cause:
A software task has failed, causing a delay in the routine running of the code on the Graphics Board. If
the delay is long enough, a hardware timer in the processor will re-boot the processor. When the
processor comes up, it will communicate what caused the reset (watchdog vs. normal power reset.)
Watchdog resets are logged as Error 12. Power resets are not logged.
Service:
Check the cables and connections required between the MCC and the A/V device. If cabling appears
normal:
• For an embedded wireless receiver, replace the receiver and all cabling.
• For an embedded PEM, verifiy the EPEM works with the remote control and/or swap the EPEM with
a known working PEM or on to another unit to see where the problem lies.