Control Panel LED Check Flow
Follow the flow shown below to identify the location of failure on the basis of the Control Panel LED status and fix the failure.
If a number such as -1- or -2- is shown in the flow diagram box, be sure to refer to the check item table and make a judgment.
Start
-1-
Is the Control
Panel Main Power LED
blinking?
YES
-1-
Which is the
blink pattern of the Control
Panel Main Power
LED?
Pattern 1
-6-
Is the FLASH
PCB LED1
blinking?
Turn OFF the main
power, remove the Flash
PCB, and turn ON the
main power again.
-2-
Is an error code
displayed on the Control
Panel LCD?
YES
Replace the following parts.
- Flash PCB
Finish
(1) Control Panel Main Power LED is blinking / ON
Check item
Blink pattern of the Control Panel Main Power LED
NO
-1-
Is the Control
NO
Panel Main Power LED
ON?
YES
-3-
Is the LED8 of
NO
the Main Controller
PCB ON?
- Replace the micro-USB cable
YES
connecting the Main Controller PCB
(J4502) and the Control Panel Unit
(J1021). *
- Replace the mini-HDMI cable connecting
the Main Controller PCB (J4501) and the
Control Panel Unit (J1020). *
- Replace the Control Panel.
- If the above does not resolve the problem,
replace the Main Controller PCB.
Replace the following parts.
- Main Controller PCB
Pattern 2
Replace the following
parts.
- Low-voltage Power
Supply PCB
- Inlet unit- Power Supply
Cable
NO
Replace the following parts.
- Main Controller PCB
*: Note that working with 2 or more people is required to lift
the Reader/ADF when replacing the corresponding parts.
-4-
Is the Control
Panel Energy Saver LED
ON?
YES
-5-
Is DC 5V supplied to
the Main Controller PCB
J4507?
YES
Replace the following parts.
- Main Controller PCB
- Control Panel
- Two Cables ( micro-USB,
mini-HDMI ) between the
Main Controller PCB and
the Control Panel CPU
PCB. *
256
6. Troubleshooting
NO
- Replace the micro-USB
cable connecting the
Main Controller PCB
(J4501) and the Control
Panel Unit (J1020). *
NO
Replace the following parts.
- Low-voltage Power
Supply PCB
- Inlet unit
- Power Supply Cable