E614-0601-00
Detection Description
Remedy
E614-0611-00
Detection Description
Remedy
E614-0701-00
Detection Description
Remedy
Error in system on the Flash PCB
An error was detected in the license-related area. (Initialization failed at startup or I/O error at
startup)
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R2.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Obtain the necessary backup data by referring to "Appendix> Backup Data List" in the System
Service Manual.
2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
3. Replace the Main Controller PCB.
Error in system on the Flash PCB
An error was detected in the license-related area. (File could not be written in the Flash PCB after
startup or I/O error after startup)
[Related parts] R2.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Obtain the necessary backup data by referring to "Appendix> Backup Data List" in the System
Service Manual.
2. After replacing the Flash PCB, reinstall the system software using SST or a USB flash drive.
3. Replace the Main Controller PCB.
Error in file system on the Flash PCB
An error was detected in system setting value (service mode, etc.) storage area. (Initialization failed
at startup or I/O error at startup)
When this error occurs, the system has not been started normally. Therefore, it may not be
recorded in the error log.
[Related parts] R2.00
- Flash PCB
- Main Controller PCB
[Remedy] Perform the following in the order while checking whether the error is cleared. When
prioritizing clearing of the error, skip Remedies 2 and 3.
Although the error is cleared by "HD-CHECK", it may occur again. Thus, perform Remedies 1 to
4.
1. Check the related harness/cable and connector.
2. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "8", and execute "HD-CHECK". Then,
turn OFF and then ON the main power.
3. Obtain the necessary backup data by referring to "Appendix> Backup Data List" in the System
Service Manual.
4. Select COPIER> FUNCTION> SYSTEM> CHK-TYPE> "8", and execute "HD-CLEAR". Then,
turn OFF and then ON the main power to delete the data in the corresponding partition.
5. Check/replace the related parts.