3.3.5 Pulse view

To adjust parameters:
1.
Go to the Pulse view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjustment by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
Adjustable parameters:
Parameter
Pulse mode
Average current
Pulse frequency
Pulse ratio
Pulse base current
© Kemppi
Value
OFF / Auto / Manual / Double
Min = Current limit min, Max = Machine-
specific
0.2 Hz ... 300 Hz, 1 Hz step (Default = 1.0
Hz)
10 % ... 70 %, 1 % step (Default = 40 %)
10 % ... 70 %, 1 % step (Default = 20 %)
46
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
Note
When OFF is selected, pulse settings are
not visible. When Auto is selected, pulse
settings are visible but not adjustable.
When Manual is selected, pulse settings
are visible and adjustable.
These values depend also on other pulse
parameters. Maximum average current is
also limited by the machine spe-
cifications.
When AC current mode is used, the max-
imum Pulse frequency is 20 Hz.