To adjust parameters:
1.
Go to the Start & stop sequence view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjusting by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters in all welding modes:
Parameter
Trigger logic
Welding mode
Welding current
Ignition mode
Adjustable parameters in continuous welding:
Parameter
Pre gas
Search arc
Upslope
© Kemppi
Value
2T / 4T / 4T LOG / 4T LOG + Minilog
(Default = 2T)
Continuous / Spot / MicroTack
Default = 50 A
Lift TIG / High frequency (HF) ignition
Value
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
OFF / 5 % ... 90 %, step 1 % (Default = OFF)
OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0
s)