Power Source Mastertig 235Acdc - Kemppi MasterTig 325DC Operating Manual

Hide thumbs Also See for MasterTig 325DC:
Table of Contents

Advertisement

6.1 Power source MasterTig 235ACDC

MASTERTIG
Feature
Mains connection cable
Mains connection voltage
Maximum supply current
Effective supply current
Fuse
No-load voltage (U
No-load voltage (U
No-load voltage (U
Open circuit voltage (average)
Rated maximum output at 40 °C
(240 V)
(Duty cycle and process specified in
the next column)
Rated maximum output at 40 °C
(110 V)
(Duty cycle and process specified in
the next column)
Range of output (240 V)
Range of output (110 V)
Power factor, λ
Efficiency, ƞ
Idle power
Operating temperature range
Storage temperature range
EMC class
Degree of protection
© Kemppi
Description
1~ 50/60 Hz
)
MMA
r
)
MMA/TIG
0
)
MMA
r VRD
MMA
40 % TIG
60 % TIG
100 % TIG
37 % MMA
60 % MMA
100 % MMA
40 % TIG
60 % TIG
100 % TIG
40 % MMA
60 % MMA
100 % MMA
TIG
MMA
TIG
MMA
230 V, MMA 180 A /
27.2 V
230 V, MMA 120 A /
24.8 V
TIG
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
235ACDC GM
Value
2
1~, 2.5 mm
110 / 220...240 V ±10 %
27 A
16 A
16 A
50 V
91 V
23 V
50 V
230 A / 19.2 V
200 A / 18 V
170 A / 16.8 V
180 A / 27.2 V
150 A / 26 V
120 A / 24.8 V
130 A / 15.2 V
120 A / 14.8 V
90 A / 13.6 V
85 A / 23.4 V
75 A / 23.0 V
55 A / 22.2 V
3 A / 1 V ... 230 A / 31 V
10 A / 10 V ... 180 A / 40 V
3 A / 1 V ... 130 A / 24 V
10 A / 1 V ... 85 A / 35 V
0.99
84 %
20 W
-20...+40 °C
-20...+60 °C
A
IP23S
65
Operating manual - EN
235ACDC GM
(VRD locked on)
2
1~, 2.5 mm
110 / 240 V ±10 %
25 A
15 A
15 A
23 V (locked to VRD)
91 V
23 V
23 V (locked to VRD)
230 A / 19.2 V
200 A / 18 V
170 A / 16.8 V
180 A / 27.2 V
150 A / 26 V
120 A / 24.8 V
130 A / 15.2 V
110 A / 14.4 V
90 A / 13.6 V
85 A / 23.4 V
75 A / 23.0 V
55 A / 22.2 V
3 A / 1 V ... 230 A / 31 V
10 A / 10 V ... 180 A / 40 V
3 A / 1 V ... 130 A / 24 V
10 A / 1 V ... 85 A / 35 V
0.99
84 %
20 W
-20...+40 °C
-20...+60 °C
A
IP23S
1920900 / 2215

Advertisement

Table of Contents
loading

Table of Contents