Settings View - Kemppi MasterTig 325DC Operating Manual

Hide thumbs Also See for MasterTig 325DC:
Table of Contents

Advertisement

To adjust parameters:
1.
Go to the Current mode view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter to be adjusted by pressing the control knob (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob (1).
Adjustable parameters:
Parameter
Current mode
AC Waveform
AC Frequency
AC+ / AC- balance
MIX TIG AC (time) ratio
MIX TIG cycle time
MIX TIG DC level
"Welding processes and features" on page 75

3.3.7 Settings view

© Kemppi
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Value
DC- / DC+ / AC / MIX
Sine / Optima / Square (Default: Optima)
30 Hz ... 250 Hz (Default = 60 Hz)
Min/Max = -60 % ... 0 % (Default = -25%)
Min/Max = 10 % ... 90 %, step 1 % (Default = 50 %)
Min/Max = 0.1 s ... 1.0 s, step 0.1 s (Default = 0.6 s)
Min/Max = 50 % ... 150 %, step 1 % (Default = 100 %)
48