3.3.5 Pulse view

To adjust parameters:
1.
Go to the Pulse view.
2.
Turn the control knob (1) to browse through the parameters.
3.
Select a parameter for adjustment by pressing the control knob button (1).
4.
Adjust the parameter by turning the control knob (1).
5.
Close the parameter setting by pressing the control knob button (1).
Adjustable parameters:
Parameter
Pulse mode
Average current
Pulse frequency
Pulse ratio
Pulse base current
Pulse current
Adjusting one Pulse parameter value has an effect on the other values as well.
© Kemppi
Value
OFF / Auto / Manual / Double
Min = Current limit min, Max = Machine-
specific
0.2 Hz ... 300 Hz, 1 Hz step (Default = 1.0 Hz)
10 % ... 70 %, 1 % step (Default = 40 %)
10 % ... 70 %, 1 % step (Default = 20 %)
10 A ... 300 A, 1 A step
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Note
When OFF is selected, pulse settings are not visible.
When Auto is selected, pulse settings are visible but not
adjustable. When Manual is selected, pulse settings are
visible and adjustable.
These values depend also on other pulse parameters.
Maximum average current is also limited by the
machine specifications.
When AC current mode is used, the maximum Pulse fre-
quency is 20 Hz.
These values depend also on other pulse parameters.
Maximum pulse current is also limited by the machine
specifications.