Kemppi MasterTig 325DC Operating Manual page 45

Hide thumbs Also See for MasterTig 325DC:
Table of Contents

Advertisement

Parameter
Hot start level
Hot start time
Minilog level
Downslope
Tail arc
Post gas
Adjustable parameters in spot welding:
Parameter
Pre gas
Upslope
Spot time
Downslope
Post gas
Adjustable parameters in MicroTack welding:
Parameter
Pre gas
MicroTack spot time
MicroTack pause time
MicroTack spot count
Post gas
"Welding processes and features" on page 75
© Kemppi
Value
-80 % ... 100 %, 1 % step (Default = OFF, 0
%)
0.1 s ... 5.0 s, 0.1 s step (Default = 1.2 s)
-99 % ... 125 %, 1 % step (Default = OFF, 0
%)
OFF / 0.1 s ... 15.0 s (Default = 0.1 s)
OFF / 5 % ... 90 % (Default = OFF)
0.1 s ... 30.0 s / AUTO, 0.1 s step
Value
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
OFF / 0.1 s ... 5.0 s, 0.1 s step (Default = 0.0
s)
0.0 s ... 10.0 s, step 0.1 s (Default = 2.0 s)
OFF / 0.1 s ... 15.0 s (Default = 0.1 s)
0.1 s ... 30.0 s / AUTO, 0.1 s step (Default =
Auto)
Value
0.0 s ... 10.0 s, Auto, 0.1 s step (Default =
Auto)
1 ms ... 200 ms, step 1 ms (Default = 10
ms)
50 ms ... 500 ms, step 1 ms (Default = 50
ms)
1 ... 5 / endless, step 1 (Default = 1)
0.1 s ... 30.0 s / AUTO, 0.1 s step (Default =
Auto)
45
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
Note
This is not available with 4T trigger logic.
Note
Note
This is not visible in the settings if the
MicroTack pulse count is only 1.
If Lift TIG is used, MicroTack graph shows
only 1 spot and the spot count para-
meter is not visible.
1920900 / 2215