D9412GV2/D7412GV2 | Program Entry Guide | 2.0

A# Single Ring

Default:
No
Selection:
Yes or No
Yes
One bell output per arming period.
After one alarm, alarms on any Non-
fire points in the same area cannot
restart the bell until the armed state
changes. An alarm on a different point
in same area restarts bell output.
No
Restart bell output with each alarm
event.
Determines if an alarm from a non-fire point can
restart the alarm bell time with each Alarm Event, or
only start alarm output once per arming period.
This does not silence the keypad alarm bell tone, or
prevent any reports. This feature does not affect Fire
points. Fire points restart bell time with each new
alarm.
If and alarm occurs on a 24-hour point
while the area is disarmed, arming that
area with a key switch does not clear the
A# Single Ring flag.
Silencing the bell resets A# Single Ring.

A# Bell Test

Default:
No
Selection:
Yes or No
Yes
Start Bell Test.
No
Do not start Bell Test.
Provides alarm output from the relay programmed at
A# Alarm Bell
after the Closing Report is confirmed
or the exit delay time expires.
Bosch Security Systems | 5/05 | F001U003636B
GV2MAIN
Bell Test After Confirmation
In areas that send Opening and Closing Reports, the
Bell Test occurs after the control panel sends the
Closing Report and receives an acknowledgment from
the central station receiver. For proper operation of the
Bell Test after closing confirmation, the following rules
apply:
The control panel must send Opening and Closing
Reports to the central station.
Do not use restricted openings and closings or
Opening and Closing Windows.
Area Armed Confirmation
In areas that do not report opening and closing
activity, the alarm bell relay output for this area
activates for 2 seconds after exit time expires.
Multiple Bell Tests occur: When more
than one area is armed at the same time
(such as using the ARM ALL AREAS?
function), the bell rings for 2 seconds with a
2 second pause between each bell
activation if all areas have the same exit
delay time programmed. Otherwise, the Bell
Test occurs as each area arms and it
completes its exit delay time.
When areas arm simultaneously and
report to the central station, the Bell Test
occurs as the central station receiver
confirms each area.
2.9.5

Open/Close Options

Programming determines if Opening, All Normal
Closing, and Force Arm/Bypass Closing Events are
sent to the remote central station. Without remote
reports, all control panel and area arming (Closing
Events) and disarming (Opening Events) default to
local events.
Use this programming category to determine which
opening and closing supervision characteristics are
needed.
There are three ways to generate reports from the
control panel. You can generate reports by account, by
area, or a combination of both.