3021 sori
Orientation
rotation
speed
3022 sgear
Encoder gear
ratio
3023 smini
Minimum
rotation
speed
3024
sout
Spindle
(PR)
connection
3025 enc-on
Spindle
encoder
3026 cs_ori
Selection of
winding in
orientation
mode
3027 cs_syn
Selection of
winding in
spindle
synchronou
s mode
3028 sprcmm
L system tap
cycle spindle
forward run/
reverse run M
command
8. Spindle Parameters
8.1 Spindle Base Specifications Parameters
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle
rotates at the constant rotation speed.
Set the gear ratio of the spindle to the encoder.
Set the minimum rotation speed of the spindle.
If an S command instructs the rotation speed
below this setting, the spindle rotates at the
minimum rotation speed set with this parameter.
Set the type of the spindle to be connected.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
Set connection information of the spindle
encoder.
0: No connection
1: Spindle connection (Spindle encoder
connection check function valid.)
2: Serial connection of encoder
0: Perform orientation using the winding
selected when the orientation command is
issued.
1: Use winding L whenever the orientation
command is issued.
0: The winding H/L is selected by the actual
spindle rotation speed (calculated from
commanded rotation speed) when spindle
synchronous control starts. (The winding is
not switched during synchronous control.
The control is carried out with the winding
selected at start.)
If the actual spindle rotation speed is less
than SP020, the winding L is selected, and if
more than the value, the winding H is
selected.
1: Use winding H whenever the spindle
synchronous command is issued.
Set the M code of the spindle forward run/reverse
run command.
High-order three digits :
The spindle forward run command's M code
is set.
Low-order three digits :
The spindle reverse run command's M code
is set.
176
Get other manuals https://www.bkmanuals.com
Details
Setting range
(Unit)
0 to 32767 (r/min)
0: 1/1
1: 1/2
2: 1/4
3: 1/8
0 to 32767 (r/min)
0 to 5
0 to 2
0/1
0/1
0 to 999999