No.
Items
3308 SP108 CSP3
Deceleration
rate 3 in
orientation
mode
3309 SP109 CSP4
Deceleration
rate 4 in
orientation
mode
3310
SP110
to
to
3313
SP113
3314 SP114 OPER
Orientation
pulse miss
check value
3315 SP115 OSP2
Orientation
motor speed
clamp value
2
3316 SP116 OPYVR Minimum
excitation
value after
changeover
(2nd
minimum
excitation
rate)
3317 SP117 ORUT
3318 SP118 ORCT
Number of
orientation
retry times
3319 SP119 MPGH
Orientation
position gain
H winding
compensa-
tion magnifi-
cation
8. Spindle Parameters
8.3 MDS-B-SP/SPH, MDS-C1-SP/SPH
Set the deceleration rate in orientation mode
corresponding to the gear 010.
When this parameter is set to "0", same as
SP006 (CSP).
Set the deceleration rate in orientation mode
corresponding to the gear 011.
When this parameter is set to "0", same as
SP006 (CSP).
Use not possible.
An alarm "5C" will occur if the pulse miss
value at the orientation stop exceeds this
setting value. (Note that this is invalid when
set to "0".)
In this parameter, set the value to fulfill the
following conditions.
SP114 setting value > 1.5 × SP004
(orientation in-position width)
When the orientation clamp speed is
changed by the control input, this parameter
setting will be used instead of SP005: OSP.
Indexing speed clamp valid
This parameter is used when (SP097:
SPEC0-bit4 = 1).
Minimum excitation rate when position
control input or external input is selected.
This is used by Mitsubishi.
Set to "0" unless particularly designated.
Set the number of times to retry when an
orientation or feedback error occurs.
The warning (A9) is issued while retrying
orientation, and an alarm (5C) is issued
when the set number of times is exceeded.
Set the compensation magnification of the
orientation position loop gain for the H
winding.
H winding orientation position loop gain
= SP001 (or SP002) × SP119/256
When set to "0", will become the same as
SP001 or SP002.
218
Get other manuals https://www.bkmanuals.com
Details
Setting
Standard
range
setting
0 to 1000
0
0 to 1000
0
0
0 to 32767
0
(360°/4096)
0 to 32767
0
(r/min)
0 to 100 (%) 0
0
0
0 to 100
0
(time)
0 to 2560
0
(1/256-fold)