Mitsubishi Electric MELDAS C6 Parameter Manual page 301

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

No.
Name
101
Cont1
Control
(PR)
parameter 1
16. Auxiliary Axis Parameters
Details
This is a HEX setting parameter. Set bits without a description to their default
values.
bit
F
E
D
Default
0
0
0
value
bit
Meaning when "0" is set
0
High-speed zero point return
1
after establishment of zero point.
2
3
4
5
6
7
Reference point return direction
8
(+)
Rotation direction determined by
9
operation control signal (DIR)
Machine basic position becomes
A
the origin point
B
C
Coordinate zero point creation
D
valid
Rotation direction in operation
E
control signal (DIR) or in the
shortcut direction
Stopper direction is positioning
F
direction
295
Get other manuals https://www.bkmanuals.com
C
B
A
9
8
7
0
0
0
1
0
0
Meaning when "1" is set
Dog-type return for each zero
point return operation.
Reference point return direction
(–)
Rotation direction in the shortcut
direction
Electrical zero point becomes the
origin point
Zero point established at power
supply ON position
Rotation direction in the random
position command sign direction
Stopper direction is in the sign
direction of the stopper amount
Default
Setting range
value
6
5
4
3
2
1
0
0
0
0
0
0
0
0