Mitsubishi Electric MELDAS C6 Parameter Manual page 70

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
21102 add02
Servo
(bit0)
parameter
100-point
compliance
add02
External
(bit1)
search
time-out valid
add02
RIO
(bit2)
communi-
cation
interruption
alarm invalid
21103 add03
(bit0)
add03
Amp S/W
(bit1)
automatic
download
valid
(only C64T)
21104 add04
Sampling
(bit0)
mode
selection
5. Base Specifications Parameters
Details
0: The number of servo parameters is set to 64
points.
1: The number of servo parameters is set to 100
points when using the 100-point servo parameter
compliant amplifier.
(This is compatible from software version C1 and
higher.)
0: Time-out check of the external search command
(DDBS) is not performed.
1: Time-out is performed approx. 3 seconds after
the external search command (DDBS) is issued.
(This is compatible from software version C2 and
higher.)
0: The alarm "RIO communication interrupted"
will occur if the remote I/O unit is not mounted.
1: Any alarm will not occur evenif the remote I/O
unit is not mounted. Set "1" if the remote I/O unit
is not used though CC-Link, MELSECNET/10,
etc. is used.
(This is compatible from software version C3 and
higher.)
Reserved for system.
Specify whether to perform or not the automatic
download of the amp software when the power is
turned ON.
0: Disables download
1: Enables download
(This is compatible from software version C4 and
higher.)
Select the sampling mode.
(This is compatible from software version D0 and
higher.)
0: Cycle monitor mode
1: NC alarm diagnosis mode
When NC power is turned ON, cycle monitor mode is
selected.
64
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0/1
0/1
0/1
0
0/1
(Standard:0)
0/1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents