Mitsubishi Electric MELDAS C6 Parameter Manual page 154

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

7.3 MDS-C1-Vx Standard Specification (MDS-B-Vx Compatible)
No.
Items
2236
SV036
Power
(PR)
PTYP
supply type
7. Servo Parameters
Details
F
E
D
amp
7
6
5
bit
0
When the CN4 connector of the drive unit and the power supply
are connected, setting below is necessary.
1
To validate the external emergency stop function, add 40h.
2
Set-
3
0x
1x
ting
ptyp
Not
4
x0
used
5
x1
CV-110
6
x2
7
x3
x4 CV-37
x5
CV-150
x6 CV-55
x7
x8 CV-75
x9
CV-185
8
Set the regenerative resistor type when MDS-A-CR is used.
Set-
Regenerative resistor
9
ting
model name
rtyp
MDS-C1-CV (Setting when using power supply
A
0
regeneration)
B
1
GZG200W260HMJ
GZG300W130HMJ × 2
2
3
MR-RB30
4
MR-RB50
GZG200W200HMJ × 3
5
GZG300W200HMJ × 3
6
7
R-UNIT-1
8
R-UNIT-2
9
R-UNIT-3
A to
No setting
F
C
Always set to "0".
D
amp
E
F
148
Get other manuals https://www.bkmanuals.com
C
B
A
rtyp
4
3
2
ptyp
Explanation
2x
3x
4x
CV-300
CV-220
CV-450 CV-550
CV-260
CV-370
Resistance
value
26 Ω
26 Ω
13 Ω
13 Ω
6.7 Ω
6.7 Ω
30 Ω
15 Ω
15 Ω
Setting range
9
8
1
0
5x
6x7x 8x
CR-10
CR-15
CR-22
CR-37
CR-55
CR-75
CR-90
Capacity
80W
150W
300W
500W
350W
500W
700W
700W
2100W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t