Mitsubishi Electric MELDAS C6 Parameter Manual page 69

Hide thumbs Also See for MELDAS C6:
Table of Contents

Advertisement

#
Items
21101 add01
PLC axis
(bit0)
rapid
traverse
mode
acceleration/
deceleration
type
add01
PLC axis
(bit1)
cutting feed
mode
acceleration/
deceleration
type
/Peripheral
axis (MC1K
I/F)
acceleration/
deceleration
type
add01
Circular
(bit2)
command
block overlap
valid
add01
G31
(bit3)
automatic
acceleration/
deceleration
add01
(bit4)
add01
(bit5)
5. Base Specifications Parameters
Details
Select the PLC axis rapid traverse mode acceleration/
deceleration type.
(This is compatible from software version C0 and
higher.)
0: Select constant time constant acceleration/
deceleration
1: Select constant inclination acceleration/
deceleration
(Note) This parameter cannot be used when the
peripheral axes (MC1K I/F) is used.
Select the PLC axis cutting feed mode acceleration/
deceleration type.
(This is compatible from software version C0 and
higher.)
0: Select constant time constant acceleration/
deceleration
1: Select constant inclination acceleration/
deceleration
(Note) Select the peripheral axis (MC1K I/F)
acceleration/deceleration type when the
peripheral axes are used.
(This is compatible from software version C0
and higher.)
Validates the block overlap at the circular command.
(This is compatible from software version C1 and
higher.)
0: Invalid
1: Valid
Validates dry run, override and automatic acceleration/
deceleration for the G31 (skip) command.
(This is compatible from software version C1 and
higher.)
0: Invalid
1: Valid
Reserved for system.
Reserved for system.
63
Get other manuals https://www.bkmanuals.com
Setting range (unit)
0/1
0/1
0/1
0/1
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Meldas c64Meldas c64t

Table of Contents