8.3

Environmental Specifications

ENVIRONMENTAL SPECIFICATIONS
Conformal Coating
Airflow
Temperature
Cooling Method
Operating
Storage
Vibration Sine (Operating)
Random
Shock (Operating)
Altitude (Operating)
Relative Humidity
Table 45: Environmental Specifications
8.4

MTBF Data

Calculations are made according to the standard MIL-HDBK217F-2 for following types of environment:
> Ground Benign (GB)
> Air Inhabited Cargo (AIC)
> Naval Sheltered (NS),
> Air Rotary Wing (ARW)
VX3030-RC22 0N-000
MTBF (hours)
CA.DT.A87-5e
RC - Rugged Conduction-Cooled
Standard
N.A.
VITA 47-Class CC4
Conduction
-40°C to +85°C
-45°C to +100°C
5g
/ 22-2,000 Hz
acceleration / frequency range
VITA 47-Class V3
40g
/ 20ms
peak accel. / shock duration half sine
-1,640 to 60,000 ft
95% non-condensing
GB (Hours)
25°C
40°C
479 633 h
350 811 h
Table 46: VX3030-RC22-0N000 MTBF Data
AIC (Hours)
NS (Hours)
40°C
25°C
68 202 h
97 285 h
VX3030-RC Characteristics
ARW (Hours)
40°C
55°C
78 329 h
16 765 h