KTD-S0005-0
3.5

External Real-Time Clock Battery

Voltage range:
®
Maximum current
®
English:
CAUTION ! Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer's instructions.
Deutsch:
VORSICHT ! Explosionsgefahr bei unsachgemäßem Austausch der Batterie. Ersatz nur durch den selben oder einen vom Hersteller empfohlenen
gleichwertigen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
French:
ATTENTION ! Risque d'explosion avec l'échange inadéquat de la batterie. Remplacement seulement par le même ou un type équivalent recommandé
par le producteur. L'évacuation des batteries usagées conformément à des indications du fabricant.
Danish:
ADVARSEL ! Lithiumbatteri – Eksplosionsfare ved fejlagtig Håndtering. Udskifting må kun ske med batteri af samme fabrikant og type. Lever det
brugte batteri tilbage til leverand∅ren.
Finnish:
VAROITUS ! Paristo voi rãjãhtãã, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laltevalmistajan suosittelmaan tyyppiln. Havita
kaytetty paristo valmistajan ohjeiden mukaisesti.
Spanish:
Precaución ! Peligro de explosión si la batería se sustituye incorrectamente. Sustituya solamente por el mismo o tipo equivalente recomendado por
el fabricante. Disponga las baterías usadas según las instrucciones del fabricante.
The battery of this product is not considered to be accessible by the end user. Therefore the safety instructions are only given in english, german,
french, danish, finish and spanish language.
If the battery of this product however is accessible by the end user, it is in the responsibility of the customer to give the corresponding safety
instructions in the required language(s).
3.6

Environmental Specifications

Temperature
Operating: (with appropriate airflow):
Ambient temperature: 0 to +60°C
®
Non-operating:
®
Note:
The maximum operating temperature is the maximum measurable temperature on any spot on a module's surface. You
1)
must maintain the temperature according to the above specification.
Humidity
Operating:
®
Non operating:
®
Page 8
+2.4V - +3.6V (typ. +3.0V)
10μA @ +3.0V
1)
-10 to +85°C
10% to 90% (non condensing)
5% to 95% (non condensing)