Kontron VX3030 User Manual page 45

3u vpx computing node
Table of Contents

Advertisement

VX3030 User's Guide
I2C_BOARD_CONTROL @(Base_address + 1) – when Bit 3 of this register is set to 0
Bit#
Name
7-4
Board Id
3
Check_Errors
2
Reserved
1
Reset
0
Power_OnOff
I2C_BOARD_CONTROL @(Base_address + 1) - when Bit 3 of this register is set to 1
Bit#
Name
7-4
Error Status
3
Check_Errors
2-0
Power Debug 2
CA.DT.A87-5e
Board Identification
0x0110 VX6060
0x0011 VX3030
Error Status Selection
0 Default meaning for register @ 72 and register @73
1 Select Error Status for register @ 72 and register @73
0 No Reset
1 Reset Assert
Power On/Off Control
0 = Power Off (Go to StandBy)
1 = Power On
This control bit is valid only if POWER_MODE Dip Switch
is on High State (See bit 7 of register @04 for its value)
Error Status
Bit 7 Cross Power Error
Bit 6 : Power Error
Bit 5 : Fatal Alert
Bit 4 : Power Timeout
This register is re-initialized only when Stand By power is
down.
Error Status Selection
0 Default meaning for register @ 72 and register @73
1 Select Error Status for register @ 72 and register @73
This register indicates State of Powers when a power error
occurs (falling of one of the PWRGDG_XX signals).
This register is re-initialized only when Stand By power is
down.
Bit 2 : PWRGD_P1V8S, , }
Bit 1: PWRGD_P2V5
Bit 0 : PWRGD_P3V3_6U
Description
Description
Additional Board Features
Reset
Type
0
RO
0
RW
0
RW
0
RW
0
RW
Reset
Type
0
RO
0
RW
0
RW
Page 33