Download Print this page

Vulcan-Hart VHG-C Series Operation Manual page 34

Advertisement

Available languages

Available languages

VHG SERIES GAS FRYERS
BOIL OUT PROCEDURE:
Hot oil and hot parts can cause burns.
Never run water or boil out solution through filter and motor / pump. Doing so will void
your fryer warranty.
1. Discard oil as described under FLUSH/RINSE AND DISCARD OIL section
2. Close the drain valve and fill tank with water. Use a boil out solid degreaser which can be
ordered from your local dealer. Follow the instructions on the side of the package.
Do not use chlorine or sulfate /sulfide cleaners.
3. Solution level must be between the MIN and MAX levels on the fryer tank.
4. Turn the power switch to the on position. For solid state digital models (D) and computer
models (C) models, the temperature will automatically set for 195-200°F. The water will not
achieve an active boil.
5. Use the tank brush; clean the sides, bottom and heat
exchanger tubes.
6. Unthread the Boil Out By-Pass™ drain plug and thread in
the Boil Out By-Pass™ extension tube as shown in in
Fig. 6. The larger thread end screws into the back of the
drain manifold as shown in the cutaway side view in Fig. 7.
7. Do not allow water to run through the motor/pump. Drain
the boil out solution into a bucket or place a high
temperature rated water hose on the end of the drain
extension allowing the other end to flow into a floor drain.
8. Close the drain valve and refill the tank with water. Add 1
cup (1/4 L) of vinegar to neutralize alkaline left by the
cleaner. Solution level must be between the MIN and
MAX level on the fryer tank. Press the START(V) button
on solid state knob control (A), PROGRAM(V) button on
solid state digital(D) and the CONFIRM button on
computer(C) models, to allow the solution to heat up.
Allow solution to stand for a few minutes.
9. Drain the tank by repeating step 7. Rinse thoroughly with
clear, hot water. All traces of cleaner must be removed.
Dry the tank thoroughly.
THERMAL OVERLOAD PROTECTION BUTTON:
10.Close the drain valve and add shortening.
VULCAN
Fig. 6
Fig. 7
-34-
F-47678 Rev. A (3-20)

Advertisement