VHG SERIES GAS FRYERS
1.
Thoroughly drain the fryer. Refer to DRAINING THE FRYER.
2.
Clean the fryer according to CLEANING.
3.
Push Power switch to the off position
4.
Turn off the main gas shutoff valve.
General
The KleenScreen PLUS® filtration system filters the oil as it is pumped back into its' respective
tank(s). Only one tank can be drained and filtered at a time. Under no circumstances should
more than one tank be drained at the same time.
Assembly
After unpacking, wash the filter pan, crumb basket, suction tube and filter screen assembly.
Make sure you remove the insert located inside the filter screen. Use dishwashing detergent
and warm water, (parts are dishwasher safe). Rinse the filter pan, crumb basket and filter
screen components completely and wipe all parts dry with a clean cloth.
Pull out the filter pan all the way and remove to wash.
The filter pan slides can be removed for washing by pushing the slides back into the fryer.
Then rotate the bottom of the slide toward the center of the fryer and lift out. Reverse the
procedure to install.
Slide the filter pan back into the drawer slides. Position the filter screen assembly into the
suction tube clip in the filter pan positioning the filter screen assembly flat on the bottom of
the filter pan.
Carefully line up the suction tube so that it mates with the oil receptacle block mounted on the
frame of the fryer battery. Close the filter pan drawer. See Figures 1 and 2.
SUCTION TUBE
CLIP
FILTER SCREEN LAYS FLAT ON
BOTTOM OF THE FILTER PAN
FILTER SCREEN LAYS FLAT ON
BOTTOM OF THE FILTER PAN
VULCAN
EXTENDED SHUTDOWN
KLEENSCREEN PLUS® FILTRATION SYSTEM
Fig.1
SUCTION TUBE
-24-
OIL RECEPTACLE BLOCK
OIL RECEPTACLE BLOCK
Fig.2
F-47678 Rev. A (3-20)