VHG SERIES GAS FRYERS
Turning On Solid State Digital Control
1. Open the bottom fryer door and press the power
switch to the ON position.
The controller will power on and begin the dry fire
test.
The display will cycle through showing, VATFULL?
PUSH V,TEST and VAT(timer countdown).
during the dry fire test.
If dry fire test fails, the display will cycle,
VATFULL? PUSH V.
The dry fire test can be by-passed by visually
confirming the oil level is correct, then press the
V
button.
2. After the dry fire test is either passed or manually
by-passed, the melt cycle will begin and the fryer will
heat off and on until the vat temperature exceeds
135° F.
The display will show the current melt cycle setting.
The correct melt mode must be set to match the
shortening type used. Select L(liquid), S(solid) or OFF(
no melt cycle)
Once temperature exceeds 135°F(or if set to MELT
OFF), the fryer will heat continuously until the
controller set point is reached.
3. Once the temperature reaches setpoint, the
display will show READY.
Pressing the TEMP
button will display the
actual temperature for 3 seconds.