VHG SERIES GAS FRYERS
9. Press the PROGRAM
dry fire test mode displays. Press
UP or DOWN on the PROGRAM
button to change from Y(on) or N
(off).
The dry fire test function is an important feature intended to prevent the fryer burners from turning
on with no liquid in the fry tank. It is recommended to be left in the on(Y) position. The fry tank can
be damaged if the burners are turned on while empty and will void your
11. Press the PROGRAM
and resume operations. The controller will display one of the following.
MELT – If a melt cycle has been selected and the temperature is below 135°F.
HEATING – If melt selection is OFF or temperature is above 135°F and below
the setpoint.
READY – When fryer is ready to cook.
Solid State Digital Control Timer Operation
1. Press the desired timer button(s)
4. Press and hold desired timer button for 3 seconds to cancel a cook timer.
Note : The timer with the least amount of remaining time will display when two timers are running simultaneously.
The light for the timer with the least amount of remaining time will flash faster.
Note : The timer will only activate when the display says READY. If the temperature is too low, the control displays
HEATING and will display READY once back up to temperature.
VULCAN
button, the
10. Press the PROGRAM
the locked mode displays. Press UP
or DOWN on the PROGRAM
button to change from locked or
unlocked.
button one more time to exit the program mode
2. The timer light will flash and the
timer will begin countdown.
-16-
button,
warranty.
3. Press timer button to silence
alarm when time completes.