Quantum LTO 3 User Manual page 72

Quantum lto 3: user guide
Hide thumbs Also See for LTO 3:
Table of Contents

Advertisement

SCSI Commands: 21BLOG SENSE
Bits
Byte
7
51
52
(MSB)
55
56
(MSB)
59
Multi-byte numeric fields are in big-endian format. Each field records the specified
data at the time the event occurred. If the repeat count is one or more, then the
parameter indicates that the specified event occurred multiple times in succession
without any other event type in between, and the fields contain the values
corresponding to the most recent occurrence of the event.
Field
Bytes
Page code
0
PAGE LENGTH
2-3
PARAMETER
3-5
CODE
Parameter
6
Control Byte
PARAMETER
7
LENGTH
PROTOCOL
8
IDENTIFIER
NUMBER OF
11
PHYS
PHY
13
IDENTIFIER
ATTACHED
16
DEVICE TYPE
NEGOTIATED
17
PHYSICAL LINK
RATE
Attached SSP
18
Initiator Port
Attached STP
18
Initiator Port
Attached SMP
18
Initiator port
Attached SSP
19
Target Port
Attached STP
19
Target Port
Attached SMP
19
Target port
SAS ADDRESS
20-27
ATTACHED
28-35
SAS
IDENTIFIER
ATTACHED
36
PHY
IDENTIFIER
6
5
4
LOSS OF DWORD SYNCHRONIZATION
PHY RESET PROBLEM
Bits
Description
6-0
Protocol Specific Port log page code is set to 18h
Protocol Specific Port log page length is 38h
One parameter code is returned, this field is set to 0h.
As defined in the typical Log Parameter format on page 45
Length of the following parameter, 34h
3-0
SAS Protocol Identifier, 6h
Number of PHYs, 1h
The PHY Identifier is 00h (SAS 2r00 4.2.7)
6-4
001b = End device
010b = Connected to Edge expander
3-0
Current negotiated rate, either 8h, (1.5 Gbps), or 9h, (3.0 Gbps).
(SAS 2r00 10.4.3.5)
3
0 = Serial SCSI Protocol Initiator not present
1 = Serial SCSI Protocol Initiator present
2
0 = Serial Tunneling Protocol Initiator not present
1 = Serial Tunneling Protocol Initiator present
1
0 = Serial Management Protocol Initiator not present
1 = Serial Management Protocol Initiator present
3
0 = Serial SCSI Protocol Target not present
1 = Serial SCSI Protocol Target present
2
0 = Serial Tunneling Protocol Target not present
1 = Serial Tunneling Protocol Target present
1
0 = Serial Management Protocol not present
1 = Serial Management Protocol Target present
The NAA Identification Descriptor returned by INQUIRY page 83h
The ATTACHED SAS ADDRESS is 00h (SAS 2r00 10..4.3.5)
The ATTACHED PHY IDENTIFER is 00h (SAS 2r00 10..4.3.5)
3
2
1
Page 64
0
(LSB)
(LSB)
(LSB)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lto 4