Quantum LTO 3 User Manual page 261

Quantum lto 3: user guide
Hide thumbs Also See for LTO 3:
Table of Contents

Advertisement

SRV_TCNT_RUNAWAY
SRV_CLOSED_LOOP_STEPPER_FAILED_TO_FIND_P
ES_GOING_BACKWARDS
SRV_LPOS_SET_CANDIDATE_TAPE_NOT_MOVING
SRV_LPOS_INVALID_TAPE_DIRECTION_WHEN_ENA
BLING_LIMITS
SRV_CMDPROC_INVALID_CALIB_DATA_FROM_FLAS
H
SRV_CMDPROC_CALIB_DATA_OVERWRITTEN_BY_D
EFAULTS
SRV_NEVER_SAW_SERVO_SIGNAL_DURING_BACK
WARDS
SRV_SERVO_SIGNALS_NOT_WITHIN_ACQUIRING_WI
NDOW_DURING_BACKWARDS
SRV_FAILURE_DURING_TRACKING_BAND_LOCK
SRV_FAILURE_DURING_TRACKING_BAND_LOCK_D
URING_BACKWARDS
SRV_FAILURE_DURING_TRACKING_RAMPING_DURI
NG_BACKWARDS
SRV_FAILURE_DURING_TRACKING_SETTLING_DURI
NG_BACKWARDS
SRV_FAILURE_DURING_TRACKING_PRE_TRACKING
_DURING_BACKWARDS
SRV_FAILURE_DURING_READING_DURING_BACKW
ARDS
SRV_FAILURE_DURING_WRITING_DURING_BACKWA
RDS
SRV_REEL_UNEXPECTED_ERROR_DETECTED_MES
SAGE_RECEIVED
SRV_REEL_NULL_FUNCTION_IN_ERROR_MSG_TABL
E
SRV_REEL_INVALID_MESSAGE_RECEIVED_NOT_IN_
TABLE
SRV_REEL_INVALID_STATE_VARIABLE_OUT_OF_RA
NGE
SRV_TRACKING_FAILED_TO_TIMEOUT
SRV_MOVETAPE_UNEXPECTED_LPOS_RECIEVED_I
N_CRUISE_CONTROL
SRV_CLEAN_SCRUB_LENGTH_MUST_BE_LESS_THA
N_GOTO_LPOS
SRV_MOVETAPE_TAPE_SPEED_NOT_GREATER_TH
AN_ZERO_AFTER_RAMP_UP
SRV_CMDPROC_INVALID_DRIVE_STATE_ON_CLEAN
_CMD
SRV_CMDPROC_OUT_OF_RANGE_DRIVE_STATE_ON
_CLEAN_CMD
SRV_MOVETAPE_RAMP_DOWN_FAILED_AFTER_LP
OS_HIT_IN_CRUISE_CONTROL
SRV_CMDPROC_UNKNOWN_SOURCE_FOR_MESSAG
E
SRV_MOVETAPE_TAPE_MOVEMENT_COMMANDS_A
RE_INVALID_IN_CRUISE_CONTROL
SRV_HALL_SENSORS_TOO_HIGH
SRV_HEAD_STEPPER_OFFSET_CALIBRATION_TIME
OUT_DURING_IDLE
SRV_HEAD_STEPPER_OFFSET_CALIBRATION_TIME
OUT_DURING_STARTING_SEARCH
SRV_HEAD_STEPPER_OFFSET_CALIBRATION_TIME
46Dh
Servo
ASIC TCNT register detects that the tape is running much higher
than 4.15 meter/
46Eh
Servo
Closed loop stepper failed to find pes while in backwards mode
46Fh
Servo
An attempt to enable a candidate lpos notification entry was
attempted while tap
470h
Servo
When setting limits the direction of tape movement was not
defined.
471h
Servo
Calibration data from flash has invalid values
472h
Servo
Calibration data was overwritten by setting defaults
473h
Servo
Never saw servo signal during backwards tracking.
474h
Servo
Servo signals not within acquiring window during backwards
tracking.
475h
Servo
Failure during tracking band lock
476h
Servo
Failure during tracking band lock during backwards tracking.
477h
Servo
Failure during tracking ramping during backwards tracking.
478h
Servo
Failure during tracking settling during backwards tracking.
479h
Servo
Failure during tracking pre tracking during backwards tracking.
47Ah
Servo
Failure during reading during backwards tracking.
47Bh
Servo
Failure during writing during backwards tracking.
47Ch
Servo
An asynchronous error detected message was received in a
state that would normal
47Dh
Servo
A null function in the error handling function lookup was
undefined.
47Eh
Servo
A message that does not have an entry in the table look up was
received
47Fh
Servo
The state variable is out of range.
480h
Servo
Tracking code fails to respond after failure to track.
481h
Servo
An LPOS reel notification was recieved in the cruise control
state that was not
482h
Servo
Error because goto lpos - scrub lpos length is less than 0
483h
Servo
After ramp up speed is not greater than zero
484h
Servo
Cannot execute clean command at current drive state
485h
Servo
Unknown or out of range drive state for clean command
486h
Servo
After recieving LPOS notification to ramp down
487h
Servo
unknown sender of message received in command processor
task
488h
Servo
A tape movement command was received while tape was
moving
489h
Servo
The hall sensors with reference to the head stepper unit are
locate too high. Th
48Ah
Servo
Timeout during head stepper offset calibration idle.
48Bh
Servo
Timeout during head stepper offset calibration starting search.
48Ch
Servo
Timeout during head stepper offset calibration searching for

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lto 4

Table of Contents