TAPE_WORM_BAD_CM
TAPE_WORM_BAD_CM_AND_FID_MISMATCH
SRV_VCM_HALL_DAMPING_FACTOR_NOT_WITHIN_
RANGE
SRV_SEEPROM_TEST_FAILED
TAPE_AUTO_LOAD_INVALID_CM_LP1
TAPE_AUTO_LOAD_INVALID_SRV_LP1
MIC_BAD_PROTECTED_PG_TBL
MIC_BAD_UNPROTECTED_PG_TBL
SCSI_ECHO_BUFFER_HAS_NOT_YET_BEEN_WRITTE
N
SCSI_ECHO_BUFFER_IID_MISMATCH
SRV_HW_SQRT_ILLEGAL_RADIX
SRV_HW_SQRT_TIMEOUT
SRV_HW_SQRT_INVALID_SCALE
SCSI_BOGUS_SIZE_DESC_RETRY_CNT_THRESHOLD
_BREACH
MIC_PARTIAL_INIT_LTO1
MIC_PARTIAL_INIT_LTO2
MIC_PARTIAL_INIT_LTO3
SRV_SPI_INTF_A_BUSY
TAPE_PHYS_LP3_EXCEED_MAX
SRV_EXPECTED_TO_BE_OFF_HEAD_STEPPER_SEN
SOR
SRV_EXPECTED_TO_BE_ON_HEAD_STEPPER_SENS
OR
SRV_NEVER_GOT_OFF_HEAD_STEPPER_SENSOR
SRV_NEVER_GOT_ON_HEAD_STEPPER_SENSOR
DSM_WORM_APPEND_NOT_ALLOWED
DSM_WORM_APPEND_NOT_ALLOWED_INVALID_HE
ADER
SRV_UNABLE_TO_FIND_SERVO_BAND
SRV_WRL_INTF_BUSY
SRV_PLACE_HOLDER
TRK_INVALID_ERROR_ALERT_RECEIVED
SRV_TRK_LOG_FULL
SRV_TRK_ABORT
SRV_TRK_TASK_BUSY
SRV_TRK_UNEXPECTED_MESSAGE_RESPONSE
TRK_INVALID_ALERT_RECEIVED
SRV_REJ_PARM_LP1_OR_LP6_OUT_OF_RANGE
SRV_MODE_DEPENDENT_REGS_COUNT_IS_INCORR
ECT
SRV_SPEED_DEPENDENT_REGS_COUNT_IS_INCOR
RECT
952h
Tape
The CM is not readable and the SMW indicates WORM cartridge
953h
Tape
The CM is not readable, the SMW indicates Rd/Wr cartridge and
the FID indicates
954h
Servo
Damping Factor has to be between 0.25 to 0.35
955h
Servo
Data read back do not match the data written during the serial
EEPROM test
956h
Tape
Tape Task detect invalid LP1 from CM
957h
Tape
Tape Task detect invalid LP1 from Servo
958h
Medium
protected page table corrupted
Auxiliary
Memory
959h
Medium
corrupted unprotected page table
Auxiliary
Memory
95Ah
SCSI
Write Buffer command must write to echo buffer before Read
Buffer may read it.
95Bh
SCSI
The IID for the Read Buffer command must match that of the
Write Buffer command
95Ch
Servo
95Dh
Servo
95Eh
Servo
95Fh
SCSI
Read command bogus size error threshold has been breeched
960h
Medium
LTO1 data CM is partially init or corrupted
Auxiliary
Memory
961h
Medium
LTO2 data CM is partially init or corrupted
Auxiliary
Memory
962h
Medium
LTO3 data CM is partially init or corrupted
Auxiliary
Memory
963h
Servo
When SPI controller is busy
964h
Tape
Physical LP3 exceeds maximum limit
965h
Servo
Goto head stepper sensor sequence was expecting to not be on
sensor.
966h
Servo
Goto head stepper sensor sequence was expecting to be on
sensor.
967h
Servo
Goto head stepper sensor sequence expected to untrip the
sensor.
968h
Servo
Goto head stepper sensor sequence expected to trip the sensor.
969h
Data set
Append attempt violates WORM rules.
manager
96Ah
Data set
Write from BOT violates WORM rules.
manager
96Bh
Servo
Closed loop head positioning failed to locate a servo band
96Ch
Servo
96Dh
Servo
96Eh
General
Display when invalid error is received in TRACKING_TASK
96Fh
Servo
970h
Servo
971h
Servo
972h
Servo
973h
General
974h
Servo
SET_TAPE command rejected because LP1 or LP6 out of range
975h
Servo
976h
Servo