SRV_EXT_DAC_NOT_CALIBRATED
SRV_HEAD_AZIMUTH_MAX_MEAN_EXCEEDED
SRV_HEAD_AZIMUTH_MAX_STDEV_EXCEEDED
SRV_HEAD_AZIMUTH_MAX_FWD_REV_DELTA_MEA
N_EXCEEDED
SRV_THR_TRAY_LOAD_ALREADY_AT_TRAY_IN
SRV_THR_CART_LOAD_MISSING_TRAY_IN
SRV_THR_TRAY_UNLOAD_ALREADY_AT_TRAY_OUT
SRV_THR_CART_TRAY_LOAD_STALL
SRV_THR_CART_TRAY_UNLOAD_STALL
THR_PIN_GRABBER_HALL_NO_PICK_PEAK_RECOV
ERED
SRV_MTR_LOG_FULL
SRV_MTR_UNEXPECTED_MESSAGE_RESPONSE
SRV_MTR_ABORT
SRV_MTR_TASK_BUSY
SRV_MTR_ACTIVE_FUNCTION_IS_NULL
SRV_THR_CART_RECHUCK_NEVER_GOT_OFF_TRA
Y_IN
TAPE_READ_ONLY_FORMAT
SRV_REJ_THREADED
SRV_MOTOR_BOT_OVERRUN
MTR_INVALID_ALERT_RECEIVED
MTR_INVALID_ERROR_ALERT_RECEIVED
SRV_MTR_THIS_MOTOR_IS_NOT_ROTATING
SRV_MTR_UNEXPECTED_MESSAGE_IN_IDLE_STATE
SRV_MTR_UNEXPECTED_MESSAGE_IN_ROTATE_ST
ATE
SRV_MTR_UNEXPECTED_MESSAGE_IN_POS_MOVE_
STATE
SRV_MTR_UNEXPECTED_MESSAGE_IN_HOLD_TENS
ION_STATE
SRV_MTR_UNEXPECTED_MESSAGE_IN_RAMPING_S
TATE
SRV_MTR_UNEXPECTED_MESSAGE_IN_STEADY_SP
EED_STATE
SRV_MTR_MAXIMUM_STATE_EXCEEDED
SRV_UNTHREAD_UNABLE_TO_LOCK_DRIVE_FLANG
E
SRV_THR_FLANGE_NOT_LOCKED
SRV_THR_FLANGE_STILL_LOCKED
SRV_THREAD_FLANGE_NOT_LOCKED
SRV_THR_AUTOLOAD_MECH_UNSAFE
TAPE_SRV_SPEED_NOT_IN_RANGE
DSM_CMPR_RD_CHECK_RECSIZE_BUG_NO_DS_TO_
ADD
SRV_EVENT_UNTHREAD_PIN_GRABBER_STUCK_IN_
HUB_EXCEEDED_RETRIES
SRV_UNTHREAD_PIN_GRABBER_STUCK_IN_HUB
SRV_REEL_PEOT_CAN_NOT_RAMP_IN_FORWARD
SRV_REEL_PBOT_CAN_NOT_RAMP_IN_REVERSE
SRV_VCM_BIAS_IS_NOT_CALIBRATED_USE_DEFAU
LT
SRV_PROGRAMMING_TZA_REG_BUSY
SRV_FAILURE_DURING_TRK_WAITING_FOR_ONTRA
CK_DURING_BACKWARDS
DSM_CMPR_RD_CHECK_RECSIZE_BUG_ADDR_RAN
GE
SRV_SIGMA_CALC_OVERFLOW
SRV_SIGMA_CALC_COUNT_IS_NOT_GREATER_THA
8D3h
Servo
External dac is not calibrated, use default value
8D4h
Servo
8D5h
Servo
8D6h
Servo
8D7h
Servo
Cart Tray already loaded when told to load
8D8h
Servo
Cart Loaded and never saw the TRAY IN sensor
8D9h
Servo
Tray Unload detects it is already at TRAY OUT sensor
8DAh
Servo
Cart stalled during Load
8DBh
Servo
Cart Tray stalled during Unload
8DCh
General
Pin Grabber initialization failed and recovered.
8DDh
Servo
Reel task is trying to send more commands to ISR
8DEh
Servo
Motor task recieved unexpected response
8DFh
Servo
Use for internal abort
8E0h
Servo
Motor task is busy
8E1h
Servo
Motor task try to execute null function
8E2h
Servo
Rechuck stuck at Tray In position
8E3h
Tape
report this error status when write on read-only format tape.
8E4h
Servo
Reject command because drive is threaded
8E5h
Servo
8E6h
General
8E7h
General
8E8h
Servo
Can't stop this motor b/c it is not rotating
8E9h
Servo
This command is not expected in this state
8EAh
Servo
This command is not expected in this state
8EBh
Servo
This command is not expected in this state
8ECh
Servo
This command is not expected in this state
8EDh
Servo
This command is not expected in this state
8EEh
Servo
This command is not expected in this state
8EFh
Servo
This command is not expected in this state
8F0h
Servo
Unable to Lock Drive Hub Outer Flange prior to unthreading
8F1h
Servo
Flange not locked after Flange Lock
8F2h
Servo
Flange still locked after after Flange Unlock
8F3h
Servo
Flange not locked at start of Thread process
8F5h
Servo
Autoload mechanics is unsafe
8F6h
Tape
Report Servo speed not suitable for writing or reading.
8F7h
Data set
DSM detected missing DS while performing hardware
manager
workaround
8F8h
Servo
Pin Grabber is stuck in the Drive Hub
8F9h
Servo
Pin Grabber stuck in Drive Hub
8FAh
Servo
Can't ramp forward peot point
8FBh
Servo
Can't ramp reverse past BOT point
8FCh
Servo
8FDh
Servo
8FEh
Servo
Servo Failure during tracking state waiting for ontrack in using
not default hea
8FFh
Data set
Address range error during h/w workaround
manager
900h
Servo
When gathering data for sigma calculation overflow
901h
Servo
In sigma calulation counts has to be higher then 1