Quantum LTO 3 User Manual page 257

Quantum lto 3: user guide
Hide thumbs Also See for LTO 3:
Table of Contents

Advertisement

SRV_OFF_TRACK
SRV_NO_PES_FOUND
SRV_VCM_SHOCK_ERROR
SRV_TRACKING_TARGET_OUTRANGE
SRV_TRACKING_SAMPLE_ERROR
SRV_TRACKING_COARSE_MOVE_ERROR
SRV_TRACKING_UPDATE_MEM_ERROR
SRV_MOVETAPE_RAMPDOWN_API_FAILED_IN_TRA
CKING_CMD_FAILED_HANDLER_IN_RAMP_UP_STAT
E
SRV_MOVETAPE_TRACKING_CMD_FAILED_IN_RAM
P_UP_STATE
SRV_CMDPROC_ROTATE_REEL_REJECTED_BECAU
SE_CART_LOADED
SRV_CMDPROC_ROTATE_REEL_REJECTED_BECAU
SE_DRIVE_REEL_IS_OBSTRUCTED
SRV_CMDPROC_ROTATE_REEL_REJECTED_INVALI
D_REEL_SELECT
SRV_CMDPROC_SET_DRIVE_STATE_COMMAND_RE
JECTED_STATE_OUT_OF_RANGE
SRV_STATEM_RECOVERY_COMMAND_REJECTED_D
RIVE_IN_UNKNOWN_STATE
SRV_TRKCNVT_MULTIPLY_ERROR_IN_TRACKING_C
ONVERT_FUNCTION
SRV_TRKCNVT_DIVIDE_ERROR_IN_TRACKING_CON
VERT_FUNCTION
SRV_STATEM_AUTOLOAD_COMMAND_REJECTED_I
NVALID_STATE
SRV_NOT_USED_OBSOLETE_2
SRV_STATEM_PRE_EJECT_COMMAND_REJECTED_I
NVALID_STATE
SRV_STATEM_PRE_EJECT_COMMAND_REJECTED_
DRIVE_IN_UNKNOWN_STATE
SRV_STATEM_AUTOLOAD_COMMAND_REJECTED_U
NKNOWN_STATE
SRV_TRKCNVT_DAC_OUTPUT_EXCEEDED_LIMIT
SRV_TRKCNVT_DAC_OUTPUT_BELOW_MINIMUM_LI
MIT
SRV_STEP_HEAD_EXPECTING_BOTTOM_SENSOR_H
IGH
SRV_STEP_HEAD_EXPECTING_STOP_AFTER_BOTT
OM_SENSOR_HIGH
SRV_STEP_HEAD_EXPECTING_BOTTOM_SENSOR_L
OW
SRV_STEP_HEAD_EXPECTING_STOP_AFTER_BOTT
OM_SENSOR_LOW
SRV_SZA_INTERFACE_BUSY
SRV_SZA_FUNCTION_ACTIVE
SRV_SZA_REGISTER_INVALID
SRV_SZA_READ_COUNT_TOO_LARGE
SRV_SZA_WRITE_COUNT_TOO_LARGE
SRV_SZA_WRITE_DATA_INVALID
SRV_REEL_CARTDITHER_API_CALL_FAILED_INVALI
D_STATE
SRV_SERIAL_EEPROM_FAILED
SRV_SRV_RTOS_INVALID_TASK_ID_SPECIFIED
SRV_MOTOR_POWER_FAIL_1
SRV_MOTOR_POWER_FAIL_2
SRV_MOTOR_POWER_FAIL_3
3CDh
Servo
tracking servo detected off track event
3CEh
Servo
no valid PES event
3CFh
Servo
tracking servo detected shock vibration error
3D0h
Servo
tracking servo detected unreachable track error
3D1h
Servo
tracking servo detected asic sample error
3D2h
Servo
tracking servo detected coarse stepper is out of position
3D3h
Servo
tracking servo detected PES memory failure
3D4h
Servo
Rampdown api call failed/rejected when called from tracking
command failed handl
3D5h
Servo
Tracking command failed in ramp up state
3D6h
Servo
Rotate reel command rejected because cartridge is loaded and
command is trying
3D7h
Servo
Rotate reel command rejected because reels are obstructed by
tape or a cartridge
3D8h
Servo
Rotate reel command rejected because an invalid reel select was
given
3D9h
Servo
Set drive state command rejected because the drive state is out
of range.
3DAh
Servo
Recovery command rejected
3DBh
Servo
Multiply error in tracking conversion function from ratio to dac
3DCh
Servo
Divide error in tracking conversion function from dac to ratio.
3DDh
Servo
Command rejected since the drive state was invalid (out of
range).
3DEh
Servo
Command rejected since the drive state was invalid in eject
sequence
3DFh
Servo
Command rejected since the drive state was invalid in pre-eject
sequence
3E0h
Servo
Command rejected
3E1h
Servo
Command rejected
3E2h
Servo
Calculated DAC tracking target greater than maximum input
3E3h
Servo
Calculated DAC tracking target less than minimum input
3E4h
Servo
expecting SNS9 high
3E5h
Servo
expecting SNS9 low
3E6h
Servo
expecting stepper to halt after SNS9 high
3E7h
Servo
expecting stepper to halt after SNS9 low
3E8h
Servo
interface to SZA chip busy for too long
3E9h
Servo
SZA read or write already in progress
3EAh
Servo
request to read invalid SZA register number
3EBh
Servo
amount of SZA read data exceeds buffer size
3ECh
Servo
amount of SZA write data exceeds buffer size
3EDh
Servo
SZA write data contains invalid reg or chip ID
3EEh
Servo
Call to cartDither api failed
3EFh
Servo
3F0h
Servo
invalid task specified in rtos wrapper function.
3F1h
Servo
no power to reel motor circuits on startup
3F2h
Servo
no power to reel motor circuits after POR clear
3F3h
Servo
no power to reel motor circuits after PF clear

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lto 4

Table of Contents