Quantum LTO 3 User Manual page 295

Quantum lto 3: user guide
Hide thumbs Also See for LTO 3:
Table of Contents

Advertisement

SRV_UNTHREAD_PULL_NO_STALL
SRV_UNTHREAD_PULL_UNEXPECTED_STALL
SRV_REEL_HW_DID_NOT_DETECT_STOP
SRV_PIN_GRABBER_PRE_INIT_STUCK_ZONE_A
SAS_INTERFACE_CTIO_ABORTED
SAS_INTERFACE_CTIO_CRCERROR
SAS_INTERFACE_CTIO_CRCERRORAUTOGOOD
SAS_INTERFACE_CTIO_CTIOM0SCBERR
SAS_INTERFACE_CTIO_CONNECTIONDOWN
SAS_INTERFACE_CTIO_DMAPARITYERROR
SAS_INTERFACE_CTIO_DATAPHASECRCERR
SAS_INTERFACE_CTIO_I_T_NEXUSLOSS
SAS_INTERFACE_CTIO_UNUSED
SAS_INTERFACE_CTIO_OKRESID
SAS_INTERFACE_CTIO_OKSTOP
SAS_INTERFACE_CTIO_OKSTOPAUTOGOOD
SAS_INTERFACE_CTIO_OPENTIMEOUT
SAS_INTERFACE_CTIO_PATHWAYBLOCKED
SAS_INTERFACE_CTIO_PEER_LOGOUT
SAS_INTERFACE_CTIO_XFERMISPECIFIED
SAS_INTERFACE_CTIO_XFERABORTEDCMD
SAS_INTERFACE_CTIO_WWNTABLEERR
SAS_INTERFACE_CTIO_WWNIOCOUNTERR
SAS_INTERFACE_CTIO_TASK_UNAVAIL
SAS_INTERFACE_CTIO_SHORTIU
SAS_INTERFACE_CTIO_SENDRESPSCBERR
SAS_INTERFACE_CTIO_SENDFRAMESCBERR
SAS_INTERFACE_CTIO_RETRY
SAS_INTERFACE_DETECT_WRITE_CRC_ERROR_AFT
ER_COMMAND_DONE
SRV_PIN_GRABBER_CANNOT_MOVE_OUT_TO_STA
NDBY
SRV_CMD_MEM_IS_NOT_COMPATIBLE_WITH_CNTR
L
DSM_WORM_SET_CAPACITY_NOT_ALLOWED
SCSI_DETECTED_WORM_CM_CONFLICT_IN_CART_T
YPE
SCSI_DETECTED_WORM_CM_CONFLICT_IN_MEDIA_
MFG_WORD
SCSI_DETECTED_WORM_CM_CONFLICT_IN_FORMA
T_TYPE
SRV_DOMAIN_ERROR
SCSI_SET_CAPACITY_NOT_ALLOWED_ON_INIT_WO
RM_CART
SCSI_WORM_MODE_NOT_SUPPORTED
CM_BAD_ERROR_USAGE
CM_BAD_CARTRIDGE_CONTENT
FC_INTERFACE_CTIO_ABORTED
MIC_CART_TYPE_NOT_RECOGNIZED
FC_INTERFACE_CTIO_CRCERROR
hub.
09C7h
Servo
Pulling tape to the cart reel didn't stall
09C8h
Servo
Pulling tape to cart reel stalled before the pin could reach the
grabber mover.
09C9h
Servo
This is an exception when HW does not detect stop condition
09CAh
Servo
Cannot move the pin grabber out of zone A to zone C2 during
pre-initialization.
09CBh
SCSI
Thread aborted by initiator
09CCh
SCSI
SDRAM CRC error
09CDh
SCSI
SDRAM CRC error after autogood sent
09CEh
SCSI
SAS_SSP_TGT_CtioM0Start out of rsrcs
09CFh
SCSI
Connection went down mid-transfer
09D0h
SCSI
DMA Parity error on Read
09D1h
SCSI
Data phase CRC error
09D2h
SCSI
I_T Nexus Loss Timer expired
09D3h
SCSI
Status not needed anymore
09D4h
SCSI
SSP_DL mismatch with autogood reqst
09D5h
SCSI
XferStop completed without errors
09D6h
SCSI
XferStop did full transfer+autogood
09D7h
SCSI
Open Timeout during open attempt
09D8h
SCSI
Pathway Blocked retries exhausted
09D9h
SCSI
Peer logged out while executing CTIO
09DAh
SCSI
XferData incorrectly specified
09DBh
SCSI
XferData attempted of aborted signal
09DCh
SCSI
Invalid WWN Table entry during Tx
09DDh
SCSI
WN I/O Count reached maximum value
09DEh
SCSI
Task not available
09DFh
SCSI
Short information unit received
09E0h
SCSI
SAS_SendRespFrame out of resources
09E1h
SCSI
SAS_SSP_SendFrame out of resources
09E2h
SCSI
OPEN_REJECT(RETRY) received. Retry.
09E3h
SCSI
Controller detect CRC error within SDRAM after send good
response to the host
09E4h
Servo
Cannot move pin grabber out to the standby position during
initialization.
09E5h
Servo
Controller and Servo both should have same shared memory
address space.
09E6h
Data set
Can't use SET_CAPACITY command on an initialized WORM
manager
cartridge.
09E7h
SCSI
Some CM fields indicate WORM but cartridge type is not WORM.
09E8h
SCSI
Some CM fields indicate WORM but Media Manufacturer Info
page - media mfg word n
09E9h
SCSI
Some CM fields indicate WORM but Initialization Data page
Format Type field does
09EAh
Servo
Math Function out of domain
09EBh
SCSI
SET CAPACITY is not allowed on initialized WORM cartridges
09ECh
SCSI
Drive is not configured to support WORM
09EDh
Medium
CM Error Usage page
Auxiliary
Memory
09EEh
Medium
CM Cartridge Content page
Auxiliary
Memory
09EFh
SCSI
Thread aborted by initiator
09F0h
Medium
The Cartridge Manufacturer Information page cart type is not
Auxiliary
recognized
Memory
09F1h
SCSI
SDRAM CRC error occurred during transfer.