SCSI_CREATE_SENSE_FAILED
SCSI_INITALIZE_SENSE_FAILED
SCSI_UNKNOWN_CM_EEPROM_STATE
SCSI_INVALID_LOG_PARAMETER
SCSI_INVALID_LOG_PAGE
SCSI_INVALID_LOG_PAGE_CONTROL
SCSI_PAGE_OUT_OF_RANGE
SCSI_UNKNOWN_LOG_INFO_RESPONSE
SCSI_UNKNOWN_LOG_INFO_RESPONSE_DATA_POI
NTER
SRV_CMDPROC_CMD_REJECT_ABORT_IN_PROGRE
SS
SRV_CMDPROC_CMD_REJECT_SEQUENCER_BUSY
SRV_CMDPROC_PARAMETER_OUT_OF_RANGE
SRV_CMDPROC_SETTAPETHICK_API_REJECT_BUSY
SRV_CMDPROC_SETTENSION_API_REJECT_BUSY_I
N_STATUS_REQUEST
SRV_CMDPROC_SETRADIUSCOUNTER_API_REJECT
_BUSY
SRV_CMDPROC_INVALID_COMMAND_IN_SET_PARA
METER
SRV_REEL_AT_SPEED_MESSAGE_RECEIVED_IN_IDL
E_STATE
SRV_REEL_TRACKING_MESSAGE_RECEIVED_IN_IDL
E_STATE
SRV_REEL_AT_SPEED_MESSAGE_RECEIVED_IN_HO
LD_STATE
SRV_REEL_TRACKING_MESSAGE_RECEIVED_IN_HO
LD_STATE
SRV_MOVETAPE_FORWARD_PHYSICAL_LIMIT_OVE
RRUN_DURING_RAMP_DOWN
SRV_MOVETAPE_REVERSE_PHYSICAL_LIMIT_UNDE
RRUN_DURING_RAMP_DOWN
SRV_MOVETAPE_FORWARD_PHYSICAL_LIMIT_OVE
RRUN_DURING_RAMP_DOWN_RESTART
SRV_MOVETAPE_REVERSE_PHYSICAL_LIMIT_UNDE
RRUN_DURING_RAMP_DOWN_RESTART
SRV_SEQ_SUBCOMMAND_TIMED_OUT
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R1
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R2
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R3
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R4
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R5
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R6
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R7
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R8
SRV_STEP_PWR_RECOVERY_THREAD_TAPE_ERRO
R9
SRV_MOVETAPE_RAMP_DOWN_FAILED_IN_RAMP_D
OWN_AT_LPOS_FROM_CRUISE_CONTROL_FORWAR
D
SRV_MOVETAPE_RAMP_DOWN_FAILED_IN_RAMP_D
22Ah
SCSI
SCSI Task failed to creaate microcode changed sense
22Bh
SCSI
22Ch
SCSI
22Dh
SCSI
22Eh
SCSI
22Fh
SCSI
230h
SCSI
Log page out of range
231h
SCSI
232h
SCSI
233h
Servo
Abort command rejected since already aborting.
234h
Servo
Mechanical command rejected
235h
Servo
Parameter out of range for command.
236h
Servo
API SetTapeThick failed
237h
Servo
API SetTension failed
238h
Servo
API SetRadiusCounter failed
239h
Servo
Invalid parameter in set parameter function.
23Ah
Servo
AT_SPEED message received in idle state.
23Bh
Servo
TRACKING message received in idle state.
23Ch
Servo
AT_SPEED message received in hold state.
23Dh
Servo
TRACKING message received in hold state.
23Eh
Servo
Forward Physical limit exceeded in ramp down state.
23Fh
Servo
Reverse physical limit exceeded in ramp down state.
240h
Servo
Forward physical limit exceeded in ramp down restart state.
241h
Servo
Reverse physical limit exceeded in ramp down restart state.
242h
Servo
Subcommand timeout in sequencer.
243h
Servo
The Load Arm was unable to find the Cart Bicell target zone
during Thread Power
244h
Servo
expecting SNS13 low
245h
Servo
expecting steps done
246h
Servo
failed to remove slack
247h
Servo
failed to release pin
248h
Servo
The Load Arm failed while moving to home position (in front of
the guides) durin
249h
Servo
expecting steps done
24Ah
Servo
exceeded retries
24Bh
Servo
motor stall waiting for SNS13 high
24Ch
Servo
Ramp down failed in ramp_down_at_lpos_from_cruise_control
in forward direction.
24Dh
Servo
Ramp down failed in ramp_down_at_lpos_from_cruise_control

Advertisement