5 Repair
5.7 Replacement of the transformer
Continued
8
9
10
11
Continues on next page
96
Action
Remove the four screws (pos. 2) to
loosen the Robifix connector (pos. 1).
Disconnect the male and female connect-
or. Cut the cable ties (pos. 3).
Disconnect the current sensor and tem-
perature connector from the transformer.
Remove the screws (pos. 1) and pressure
plates (pos. 2) connecting to the fixed and
movable leaf shunts.
Remove the two screws (pos. 2) holding
the transformer (pos. 1).
© Copyright 2022 ABB. All rights reserved.
Note
xx2200000347
xx2200000348
xx2200000349
xx2100000253
Product manual - GWT C9