Time interval
Every 1,000,000
weld strokes
Product manual - GWT C9
3HAA010198-001 Revision: A
Item
Maintenance
Laminated leaf
Inspect the condition of the laminated leaf shunts and
shunts
the fasteners. Verify that no abnormal wear, cracks or
deformation have occurred. See below drawing, position
12 and 13.
Damaged leaf shunts, or shunts where more than 10%
of the shunts are damaged, may cause severe over-
heating. This will ultimately cause destruction of the C9
welding gun.
If necessary:
xx2200000327
© Copyright 2022 ABB. All rights reserved.
4.2 Maintenance planning
WARNING
Retighten the bolted joints. See
tightening torques on page
Replace damage leaf shunts by following proced-
ure
Replacement of the leaf shunts on page
Continues on next page
4 Maintenance
Continued
Bolt, screws,
118.
87.
67