ABB GWT C9 Product Manual page 101

Table of Contents

Advertisement

28
29
30
31
Product manual - GWT C9
3HAA010198-001 Revision: A
Action
Reassemble the Robifix connector. Start
by connecting the male and female con-
nectors.
Mount the Robifix connectors (pos. 1) to
the welding gun by tightening the screws
(pos. 2) with a tightening torque of 3 Nm.
Mount new cable ties (pos. 3) to secure
the cables.
When parts are reassembled, reassemble
the protective cover.
Tip
If the protective cover does not fit, adjust
the two screws (pos. 1) holding the sec-
ondary leader.
Keep in mind the alignment of the mov-
able leaf shunt.
© Copyright 2022 ABB. All rights reserved.
5.7 Replacement of the transformer
Note
xx2200000347
See
Remove/reassemble the protective
cover on page
79.
xx2200000359
5 Repair
Continued
101