Cabling Replacement Parts; Preparation Procedures; Power Down The Server - HPE Apollo 4200 Gen10 Plus Maintenance And Service Manual

Table of Contents

Advertisement

Use caution when installing the server in or removing the server from the chassis.
Adequately stabilized the chassis before extending a component outside the chassis. Extend only one component
at a time. A chassis may become unstable if more than one component is extended.
Do not stack anything on top of rail-mounted component or use it as a work surface when extended from the rack.
WARNING:
WARNING:
To reduce the risk of personal injury or damage to the equipment, observe the following precautions:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack if it is a single-rack installation.
The racks are coupled together in multiple-rack installations.
WARNING:
WARNING:
To reduce the risk of personal injury or equipment damage when unloading a rack:
At least two people are needed to safely unload the rack from the pallet. An empty 42U rack can weigh as much as
115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might become unstable when being moved on its casters.
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle the rack from both
sides.
CAUTION:
CAUTION:
Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first,
and continue to populate the rack from the bottom to the top.
CAUTION:
CAUTION:
Before installing the server in a chassis, be sure to properly scope the limitations of the chassis. Before proceeding with
the installation, consider the following:
You must fully understand the static and dynamic load carrying capacity of the chassis and be sure that it can
accommodate the weight of the server.
Be sure sufficient clearance exists for cabling, installation and removal of the server, and movement of the rack
doors.
IMPORTANT:
IMPORTANT:
The HPE Apollo 4200 Gen10 Plus Server cable management arm is not supported on Compaq-branded 7000 series
racks.

Cabling replacement parts

Cabling replacement parts
If you are replacing an assembly that includes a cable, you are not required to replace the current cable with the new cable from the
assembly. If the current cable is still functioning properly, you can keep the current cable in place.

Preparation procedures

Preparation procedures

Power down the server

Power down the
server
HPE Apollo 4200 Gen10 Plus Server Maintenance and Service Guide
18