9. PARAMETERS
No.
Symbol
PTE094
**SECB2
SSI - Ch. B function setting 2
Set basic information of ch. B encoder when SSI is selected.
Setting digit
PTE095
**SECB3
SSI - Ch. B function setting 3
Set multi-turn data of ch. B when SSI is selected.
Setting digit
PTE096
**SECB4
SSI - Ch. B function setting 4
Set single-turn data of ch. B when SSI is selected.
Setting digit
PTE097
**SECB5
SSI - Ch. B function setting 5
Set the status data of ch. B when SSI is selected.
Setting digit
Name and function
_ _ x x
Effective data length setting
Set the effective data length of the encoder.
A value of 20h or over will be fixed to 20h.
Set the effective data length converted to hexadecimal
value. For example, set "0Ch" when the effective data
length is 12 bits. Set "19h" when the effective data
length is 25 bits.
Setting range: 0h to 2Fh
x x _ _
Bit shift amount setting
Set a bit shift amount from the start of the encoder
data.
Setting range: 0h to 1Fh
_ _ x x
Multi-turn data - Data length
Set the data length of the multi-turn data.
A value of 20h or over will be fixed to 20h.
Setting range: 0h to 2Fh
x x _ _
Multi-turn data - Start bit position setting
Set the start bit position of the multi-turn data.
Setting range: 0h to 1Fh
_ _ x x
Single-turn data - Data length setting
Set the data length of the single-turn data.
A value of 20h or over will be fixed to 20h.
Setting range: 0h to 2Fh
x x _ _
Single-turn data - Start bit position setting
Set the start bit position of the single-turn data.
Setting range: 0h to 1Fh
_ _ x x
Status data - Data length setting
Set the data length of the status data.
A value of 20h or over will be fixed to 20h.
Setting range: 0h to 2Fh
x x _ _
Status data - Start bit position setting
Set the start bit position of the status data.
Setting range: 0h to 1Fh
Explanation
Explanation
Explanation
Explanation
9 - 89
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
Setting
range

Advertisement

Table of Contents