Mitsubishi Electric MELSERVO MR-MT2010 Instruction Manual page 115

General-purpose ac servo
Table of Contents

Advertisement

9. PARAMETERS
No.
Symbol
PTA038
*LO2
Level output function - Setting group 2 - Detailed setting 1
Select a signal for the setting group 2 of the level output function.
Setting digit
PTA039
LONL2
Level output function - Setting group 2 - Lower limit setting - Lower
Set the lower digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTA040] and
lower [Pr. PTA039].
PTA040
LONH2
Level output function - Setting group 2 - Lower limit setting - Upper
Set the upper digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTA040] and
lower [Pr. PTA039].
PTA041
LOFL2
Level output function - Setting group 2 - Upper limit setting - Lower
Set the lower digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTA042] and
lower [Pr. PTA041].
PTA042
LOFH2
Level output function - Setting group 2 - Upper limit setting - Upper
Set the upper digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTA042] and
lower [Pr. PTA041].
Name and function
_ _ _ x
Module selection
Select a module to be used for the level output
function.
0: Unused
1: 1st extension module
2: 2nd extension module
3: 3rd extension module
4: 4th extension module
_ _ x _
Channel selection
Select a channel to be used.
Set as shown in Table 9.1 in [Pr. PTA033] according
to the module to be used.
_ x _ _
For manufacturer setting
x _ _ _
Explanation
9 - 28
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
0000h
0000h
0000h
0000h
Setting
range
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh

Advertisement

Table of Contents
loading

Table of Contents