9. PARAMETERS
No.
Symbol
PTB005
*IDI31
DI3 (CN1-11) setting 1
Set a function for the input signal DI3 (CN1-11).
Setting digit
PTB006
*IDI32
DI3 (CN1-11) setting 2
Set a function for the input signal DI3 (CN1-11).
Setting digit
PTB007
*IDI41
DI4 (CN1-2) setting 1
Set a function for the input signal DI4 (CN1-2).
Setting digit
PTB008
*IDI42
DI4 (CN1-2) setting 2
Set a function for the input signal DI4 (CN1-2).
Setting digit
Name and function
_ _ _ x
Polarity selection
Select a polarity for the input signal.
0: Positive polarity
1: Negative polarity
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
_ _ _ x
Function selection
Select a function for the digital input signal.
0: Digital input
1: Timing latch input
_ _ x _
Digital input signal edge selection
Select an edge for the timing latch input.
0: Rising edge
1: Falling edge
_ x _ _
For manufacturer setting
x _ _ _
_ _ _ x
Polarity selection
Select a polarity for the input signal.
0: Positive polarity
1: Negative polarity
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
_ _ _ x
Function selection
Select a function for the digital input signal.
0: Digital input
1: Timing latch input
_ _ x _
Digital input signal edge selection
Select an edge for the timing latch input.
0: Rising edge
1: Falling edge
_ x _ _
For manufacturer setting
x _ _ _
Explanation
Explanation
Explanation
Explanation
9 - 30
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
Setting
range

Advertisement

Table of Contents
loading

Table of Contents