9. PARAMETERS
No.
Symbol
PTB099
ILONL6
Level output function - Setting group 6 - Lower limit setting - Lower
Set the lower digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB100] and
lower [Pr. PTB099].
PTB100
ILONH6
Level output function - Setting group 6 - Lower limit setting - Upper
Set the upper digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB100] and
lower [Pr. PTB099].
PTB101
ILOFL6
Level output function - Setting group 6 - Upper limit setting - Lower
Set the lower digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB102] and
lower [Pr. PTB101].
PTB102
ILOFH6
Level output function - Setting group 6 - Upper limit setting - Upper
Set the upper digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB102] and
lower [Pr. PTB101].
PTB103
*ILO7
Level output function - Setting group 7 - Detailed setting 1
Select a signal for the setting group 7 of the level output function.
Setting digit
PTB104
ILONL7
Level output function - Setting group 7 - Lower limit setting - Lower
Set the lower digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB105] and
lower [Pr. PTB104].
PTB105
ILONH7
Level output function - Setting group 7 - Lower limit setting - Upper
Set the upper digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB105] and
lower [Pr. PTB104].
PTB106
ILOFL7
Level output function - Setting group 7 - Upper limit setting - Lower
Set the lower digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB107] and
lower [Pr. PTB106].
PTB107
ILOFH7
Level output function - Setting group 7 - Upper limit setting - Upper
Set the upper digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB107] and
lower [Pr. PTB106].
Name and function
_ _ _ x
Module selection
Select a module to be used for the level output
function.
0: Unused
1: 1st extension module
2: 2nd extension module
3: 3rd extension module
4: 4th extension module
_ _ x _
Channel selection
Select a channel to be used.
Set as shown in Table 9.2 in [Pr. PTB073] according to
the module to be used.
_ x _ _
For manufacturer setting
x _ _ _
Explanation
9 - 57
Initial value
[Unit]
0000h
0000h
0000h
0000h
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
0000h
0000h
0000h
0000h
Setting
range
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh