9. PARAMETERS
No.
Symbol
PTC073
*IDO5A1
DO5A (CN1-13) setting 1
Set a function for the output signal DO5A (CN1-13).
Setting digit
PTC074
*IDO5A2
DO5A (CN1-13) setting 2
Set a function for the output signal DO5A (CN1-13).
Setting digit
Name and function
_ _ _ x
Polarity selection
Select a polarity for the digital output.
0: Positive polarity
1: Negative polarity
_ _ x _
Output CLEAR/HOLD function selection
Set the output status of the digital output signal for a
communication shut-off.
0: CLEAR
The digital output signal will be in the initial status
when the communication is shut off.
1: HOLD
The previous digital output signal status will be held
even when the communication is shut off.
When "Pulse coincidence output (_ _ _ 1)" is selected
with "function selection" of [Pr. PTC074], this digit will
be always set to "CLEAR" regardless of the setting
value.
_ x _ _
For manufacturer setting
x _ _ _
_ _ _ x
Function selection
Select a function for the digital output signal.
0: Digital output
1: Pulse coincidence output
When "Pulse input function (_ _ _ 0)" is selected with
"I/O function selection" of [Pr. PTC001], this digit will
be always set to "digital output" regardless of the
setting value.
_ _ x _
For manufacturer setting
_ x _ _
x _ _ _
Explanation
Explanation
9 - 71
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h