9. PARAMETERS
No.
Symbol
PTB073
*ILO1
Level output function - Setting group 1 - Detailed setting 1
Select a signal for the setting group 1 of the level output function.
Setting digit
Setting value
Note. The digital output will be off if an alarm is generated in the selected module.
PTB074
ILONL1
Level output function - Setting group 1 - Lower limit setting - Lower
Set the lower digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB075] and
lower [Pr. PTB074].
PTB075
ILONH1
Level output function - Setting group 1 - Lower limit setting - Upper
Set the upper digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB075] and
lower [Pr. PTB074].
PTB076
ILOFL1
Level output function - Setting group 1 - Upper limit setting - Lower
Set the lower digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB077] and
lower [Pr. PTB076].
PTB077
ILOFH1
Level output function - Setting group 1 - Upper limit setting - Upper
Set the upper digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB077] and
lower [Pr. PTB076].
Name and function
_ _ _ x
Module selection
Select a module to be used for the level output
function.
0: Unused
1: 1st extension module
2: 2nd extension module
3: 3rd extension module
4: 4th extension module
_ _ x _
Channel selection
Select a channel to be used.
Set as shown in Table 9.2 according to the module to
be used.
_ x _ _
For manufacturer setting
x _ _ _
Table 9.2 Level output function channel selection
MR-MT2200
pulse I/O module
0
AX.A
1
AX.B
2
3
8
9
A
B
Explanation
Module (Note)
MR-MT2300
analog I/O module
encoder I/F module
Analog input ch. 1
Analog input ch. 2
Analog input ch. 3
Analog input ch. 4
Analog output ch. 1
Analog output ch. 2
Analog output ch. 3
Analog output ch. 4
9 - 53
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
MR-MT2400
Ch. A
Ch. B
0000h
0000h
0000h
0000h
Setting
range
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh