Mitsubishi Electric MELSERVO MR-MT2010 Instruction Manual page 145

General-purpose ac servo
Table of Contents

Advertisement

9. PARAMETERS
No.
Symbol
PTB108
*ILO8
Level output function - Setting group 8 - Detailed setting 1
Select a signal for the setting group 8 of the level output function.
Setting digit
PTB109
ILONL8
Level output function - Setting group 8 - Lower limit setting - Lower
Set the lower digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB110] and
lower [Pr. PTB109].
PTB110
ILONH8
Level output function - Setting group 8 - Lower limit setting - Upper
Set the upper digits for the lower limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB110] and
lower [Pr. PTB109].
PTB111
ILOFL8
Level output function - Setting group 8 - Upper limit setting - Lower
Set the lower digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB112] and
lower [Pr. PTB111].
PTB112
ILOFH8
Level output function - Setting group 8 - Upper limit setting - Upper
Set the upper digits for the upper limit with the level output function.
Set with 32-bit signed hexadecimal values by combining upper [Pr. PTB112] and
lower [Pr. PTB111].
Name and function
_ _ _ x
Module selection
Select a module to be used for the level output
function.
0: Unused
1: 1st extension module
2: 2nd extension module
3: 3rd extension module
4: 4th extension module
_ _ x _
Channel selection
Select a channel to be used.
Set as shown in Table 9.2 in [Pr. PTB073] according to
the module to be used.
_ x _ _
For manufacturer setting
x _ _ _
Explanation
9 - 58
Initial value
[Unit]
Refer to the Name and
function column.
Initial value
0h
0h
0h
0h
0000h
0000h
0000h
0000h
Setting
range
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh
0000h
to
FFFFh

Advertisement