Default Settings And Ranges; Table 4 Flexmax Settings - Alpha Group OutBack Power FLEXmax Series Owner's Manual

Charge controllers
Table of Contents

Advertisement

Specifications

Default Settings and Ranges

Mode
Menu Item
Current Limit (FLEXmax 80)
Current Limit (FLEXmax 60)
Charger
Absorbing
Float
Vent Fan
Volts
PV Trigger
Hold Time Sec
PV VOLTS
ERROR OUTPUT
ERROR LOW BAT
VOLTS
Night Light
ON Hysteresis Time
(Minutes)
On Time (Hours)
Threshold Voltage
Aux
Float
Diversion:Relay
Hold Time (Seconds)
Delay Time (Seconds)
Absorb-Float-EQ
Relative Volts
HYST
Diversion:Solid St
Hold Time (Seconds)
Delay Time (Seconds)
Absorb-Float-EQ
Relative Volts
HYST
94
Table 4
FLEXmax Settings
Setting
Mode
Default 80 Adc
Range: 5 to 80 Adc
Default 60 Adc
Aux
Range: 5 to 60 Adc
(cont'd)
Default 14.4 Vdc
Range: Float setting to
80 Vdc
Default 13.8 Vdc
Range: 12.0 Vdc to
Absorbing setting
Default <Off>
<On, Auto, Off>
Light
Default 14.4 Vdc
Range: 10. 0 to 80.0 Vdc
Default <Off>
<On, Auto, Off>
Default 01.1 second
EQ
Range: 0 to 25 seconds
Default 140 Vdc
Range: 20 to150 Vdc
Default <Off>
<On, Auto, Off>
Default 11.5 Vdc
Range: 10 to 80 Vdc
Default <Off>
<On, Auto, Off>
Default 001 minute
Range: 001 to 255 min.
Default 04 hours
Range: 00 to 23 hours
Default 010 Vdc
Range: 005 to 150 Vdc
Default <Off>
<On, Auto, Off>
Default <Off>
<On, Auto, Off>
Default 0.1 second
Range: 0.0 to 25 sec.
Advanced
Default 0.0 seconds
Range: 0.0 to 24 sec.
Default 0.0 Vdc
Range: 0.0 to 5.0 Vdc
Default 00.2 Vdc
Range: 0.0 to12.0 Vdc
Default <Off>
<On, Auto, Off>
Default 0.1 second
Range: 0.0 to 25 sec.
Default 00 seconds
Range: 00 to 24 sec.
Default 0.0 Vdc
Range: 0.0 to 5.0 Vdc
Default 00.2 Vdc
Range: 0.0 to12.0 Vdc
Menu Item
Low Battery Disconnect
Delay Time Sec
DISCONNECT VOLTS
RECONNECT VOLTS
Remote
MODE
Auto Time
BATTERY EQUALIZE Volts
BATTERY EQUALIZE Time
EQ INTERVAL
Snooze Mode
Wakeup Mode Volts
Wakeup Mode Time
MPPT Mode
Park Mpp
MPP Range Limit (Max)
MPP Range Limit (Min)
Absorb Time Limits
Absorb End Amps
Rebulk Voltage
Vbatt Calibration
RTS Compensation
Upper Limit
RTS Compensation
Range: 10 Vdc to Upper
Lower Limit
Auto ReStart
Aux Polarity
900-0009-01-00 Rev
Setting
Default <Off>
<On, Auto, Off>
Default 01 second
Range: 000 to 250 sec.
Default 13.6 Vdc
Range: 10 to 80 sec.
Default14.4 Vdc
Range: 10 to 80 sec.
Default <Off>
<On, Auto, Off>
Default <AUTO>
<ON, AUTO, OFF>
Default 2 minutes
Range: 1 to 9 minutes
Default 14.4 Vdc
Range: Absorbing
setting to 80 Vdc
Default 01 hours
Range: 1 to 7 hours
Default 000 days
Range: 000 to 250 days
Default 0.6 Adc
Range: 0.2 to 1.0 Adc
Default 1.5 Vdc
Range: 1.5 to 9.5 Vdc
Default 05 minutes
Range: 05 to 15 min.
Default <Auto Track >
<Auto Track or
U-Pick>
Default 77% Voc
Range: 40 to 90% Voc
Default <90%>
<80, 85, 90, 99%>
Default <1/2>
<1/2 or FULL>
Default 01.0 hours
Range: 00.0 to 24 hours
Default 00 Adc
Range: 00 to 55 Adc
Default 12.0 Vdc
Range: 12.0 Vdc to
Float setting
Default 0.0 Vdc
Range: -0.5 to 0.5 Vdc
Default 14.1 Vdc
Range: Lower Limit
setting to 80 Vdc
Default 14.1 Vdc
Limit setting
Default <0>
Selections <0, 1 , 2>
Default <Active High>
<Active High or Low>
C