Specifications
Default Settings and Ranges
The settings in this table are as displayed in the MATE3 system display for a 12-volt system.
Mode
Charger
MPPT
Temperature
Compensation
Battery Equalize
Grid-Tie Mode
Auxiliary Output
66
Table 10 FLEXmax Settings (MATE3)
Menu Item
Absorb Voltage
(Absorb) Time
Float
Rebulk Voltage
Current Limit
Absorb End Amps
MPPT Mode
U-Pick VOC
Wakeup VOC Change
(Wakeup VOC) Time
Snooze Mode Amps
MPP Range Minimum
(MPP Range) Maximum
Mode
Slope
Lower Battery Voltage
Upper Battery Voltage
Equalization Voltage
(Equalization) Hours
Automatic Battery Equalization
Enable Grid-Tie Mode
Diversion:Relay
Active
Relative Voltage
Hysteresis
Hold
Delay
Setting
Default 14.4 Vdc
Range: Float setting to 80 Vdc
Default 01.0 hours Range: 00.0 to 24 hours
Default 13.8 Vdc
Range: 12.0 Vdc to Absorbing setting
Default 12.0 Vdc
Range: 12.0 Vdc to Float setting
Default 80 Adc
Range: 5 to 80 Adc
Default 00 Adc
Range: 00 to 55 Adc
Default <Auto >
<Auto> or U-Pick>
Default 77% Voc
Range: 40 to 90% Voc
Default 1.5 Vdc
Range: 1.5 to 9.5 Vdc
Default 05 minutes
Range: 05 to 15 minutes
Default 0.6 Adc
Range: 0.2 to 1.0 Adc
Default <Half>
<Half or Full>
Default <90%>
<80, 85, 90, 99%>
Default <Wide >
<Wide> or <Limited>
Default 5 mV
Range: 2 to 6 mV
Default 14.1 Vdc
Range: 10 Vdc to Upper Battery Voltage setting
Default 14.1 Vdc
Range: Lower Voltage setting to 80 Vdc
Default 14.4 Vdc
Range: Absorb Voltage setting to 80 Vdc
Default 01 hours
Range: 1 to 7 hours
Default 0 days
Range: 0 to 250 days
Default N
Range: Y or N
Default <Off>
<On, Auto, Off>
Default Active High
Range: Active High or Active Low
Default 0.0 Vdc
Range: 0.0 to 5.0 Vdc
Default 00.2 Vdc
Range: 0.0 to12.0 Vdc
Default 0.1 second
Range: 0.0 to 25 seconds
Default 0.0 seconds
Range: 0.0 to 24 seconds
900-0150-01-00 Rev A